The C32 with the upgradeable packaging design has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance to matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Generator Set Specifications
Minimum Rating830 ekW (910 kVA)
Maximum Rating1000 ekW (1250 kVA)
Voltage220 to 4160
Frequency60 Hz
Speed1800 RPM
Generator Set Configurations
Emissions/Fuel StrategyLow Fuel Consumption, Low Emissions
Engine Specifications
Engine ModelC32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore145 mm (5.71 in)
Stroke162 mm (6.38 in)
Displacement32.1 L (1958.86 in3)
Compression Ratio15.0:1
AspirationTA
Governor TypeAdem™A4
Fuel SystemMEUI
Exhaust Flange Size (Internal Diameter)203.2 mm (8.0 in)
Air InletSingle element canister style with service indicator

Cat Generator Set Packages Have Been Fully Prototype Tested, And Certified Torsional Vibration Analysis Reports Are Available. The Packages Are Designed To Accept 100% Load In One Step, Meet The Nfpa 110 Requirement For Loading, And Conform To The Iso 8528-5 Steady State And Transient Response Requirements.

The Four Cycle Cat Diesel Engine Combines Consistent Performance With Excellent Fuel Economy And Transient Response That Meets Or Exceeds Iso 8528-5. The Engines Have Been Designed And Built For A Wide Range Of Applications And Can Be Optimized For Lowest Fuel Consumption, Low Emissions, Or U.s. Environmental Protection Agency (epa) Certified Configurations. The Engines Feature A Reliable, Rugged, And Durable Design That Has Been Field Proven In Thousands Of Applications Worldwide From Emergency Standby Installations To Continuously Operating Power Plants.

The Cooling System Has Been Designed To Operate In Standard Ambient Temperatures Up To 50°c (122°f), With Optional High Ambient Radiators Available. The Factory Installed Cooling System Has Been Designed And Tested To Ensure Proper Generator Set Cooling, And Includes The Radiator, Fan, Belts, And All Guarding Installed As Standard. Contact Your Cat Dealer For Specific Ambient And Altitude Capabilities.

The Generators Used On Cat Packages Have Been Designed And Tested To Work With The Cat Engine. The Generators Are Built With Robust Class H Insulation And Provide Industry Leading Motor Starting Capability. Random Wound Generators Provide Good Generator Performance In A Majority Of Applications And Form Wound Is Available For Harsh Mechanical And Electrical Environments.

The Emcp Controller Features The Reliability And Durability You Have Come To Expect From Your Cat Equipment. The Emcp 4 Is A Scalable Control Platform Designed To Ensure Reliable Generator Set Operation, Providing Extensive Information About Power Output And Engine Operation. Emcp 4 Systems Can Be Further Customized To Meet Your Needs Through Programming And Expansion Modules.

Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries, Providing Extensive Pre-sale And Post-sale Support, From 98% Parts Availability Within 24 Hours To An Individualized Customer Support Agreement (csa), The Cat Dealer Will Provide Support.

Optional Equipment

Engine Options
  • Radiator duct flange
  • Dual element air cleaners
  • Heavy duty air cleaners
  • Muffler (industrial grade)
  • Exhaust guards / shields
  • Heavy duty electric starting motors
  • Battery Charger (10A)
  • Heavy Duty Batteries
  • Jacket water heater
  • Rubber anti-vibration mounts (90% efficient)
  • Spring type anti-vibration mounts (95% efficient)
Control System
  • EMCP (4.2) (4.3) (4.4)
  • Local annunciator module
  • Remote annunciator module
  • Expansion I/O module
  • Remote monitoring software
Generators
  • Temperature Rise over 40°C ambient: [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
  • Winding: [ ] Random [ ] Random with coastal insulation [ ] Form
  • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
  • Anti-condensation heaters
  • Generator stator and bearing temperature monitoring & protection
Power Termination
  • Circuit breaker, 100% Rated, UL Listed (fully rated)
  • Circuit breaker, IEC listed (fully rated)
  • Bus bars
Extended Service Contract
  • 2 Year Extended Service Contract (ESC)
  • 3 Year Extended Service Contract (ESC)
  • 5 Year Extended Service Contract (ESC)

listofrelationships

small_image

Other Models in this Category

Select Generator Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Steve Jamison
Power Systems Sales Manager
858.376.6821 office
858.688.0083 mobile
sjamison@hawthornecat.com

Phillip J. Smith (PJ)
Service Manager - CSA Group
858.376.6874 office
858.688.0134 mobile
psmith@hawthornecat.com

Paul Karpf
Rental Department Manager
858.376.6888 office
858.688.0039 mobile
pkarpf@hawthornecat.com

Tom Bonham
Product Support Sales Manager
858.376.6898 office
442.248.2108 mobile
tbonham@hawthornecat.com

Hawaii – Power
Cliff Yuen
Power Systems Sales Manager
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Travis Tilton
General Service Manager
808.676.0314 office
808.864.1903 mobile
ttilton@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com

Richard Nostratis
Service Manager
671.649.4212 office
671.898.2735 mobile
rnostratis@hawthornecat.com