New | 3516B Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Height - Maximum94.9 in
Length - Maximum234.4 in
Width - Maximum90 in
Engine Specifications
Bore6.69 in
Displacement - HD4764.73 in³
Displacement - Std4210.64 in³
Stroke - HD8.46 in
Stroke - Standard7.48 in

  • reliable, Rugged, Durable Design
  • field-proven In Thousands Of Applications Worldwide
  • four-stroke-cycle Diesel Engine Combines Consistent Performance And Excellent Fuel Economy With Minimum Weight
  • matched To The Performance And Output Characteristics Of Cat Engines
  • industry Leading Mechanical And Electrical Design
  • industry Leading Motor Starting Capabilities
  • high Efficiency
  • The Emcp Controller Features The Reliability And Durability You Have Come To Expect From Your Cat Equipment. Emcp4 Is A Scalable Control Platform Designed To Ensure Reliable Generator Set Operation, Providing Extensive Information About Power Output And Engine Operation. Emcp4 Systems Can Be Further Customized To Meet Your Needs Through Programming And Expansion Modules.

    The Generator Set Accepts 100% Rated Load In One Step Per Nfpa 110 And Meets Iso 8528-5 Transient Response.

  • ul 2200 Listed Packages
  • Csa Certified
  • certain Restrictions May Apply.
  • Consult With Your Cat® Dealer.
  • Fully Prototype Tested With Certified Torsional Vibration Analysis Available

    Cat Dealers Provide Extensive Post-sale Support Including Maintenance And Repair Agreements. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries. The Caterpillar S•o•s℠ Program Cost Effectively Detects Internal Engine Component Condition, Even The Presence Of Unwanted Fluids And Combustion By-products

    Standard Equipment

    Air Inlet System
    • Air Cleaner; single element canister type
    Control Panels
    • EMCP 4.2B
    • Emergency stop pushbutton
    • 24 Volt DC operation
    • Environmental sealed front face
    • Text alarm / event descriptions
    • Generator mounted - Rear facing
    • Generator set packages include Caterpillar' s Voltage Regulator. IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor
    • Controls: Speed adjust - Auto / start / stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for: RPM - DC volts - Operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
    • Warning / shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
    • Programmable protective relaying functions: Generator phase sequence - Over / Under voltage (2 7 /59) - Over / under frequency (81 o/u) - Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
    • Communications: Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Cat Connect - 3 Analog inputs - 6 Customer programmable digital inputs
    • Number of I/O varies on options selected: 4 programmable relay outputs (Form A) - 1 programmable relay outputs (Form C) - 1 programmable digital outputs
    Cooling System
    • Certified standard PGS provided
    • ATAAC - 3516E Package Radiators shipped installed
    Exhaust System
    • Dry exhaust manifold
    • Flanged faced outlet(s)
    Fuel System
    • Secondary fuel filters
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump
    General
    • Caterpillar yellow with high gloss black rails and radiator
    • Right hand servicing
    • Flywheel and flywheel housing - SAE No. 00
    • SAE Standard rotation
    Generator and Attachments
    • 3 Phase brushless, salient pole
    • 6 lead
    • Low Voltage: Random wound - Internal excitation - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
    • Medium Voltage: Form wound - Permanent magnet - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby) - Busbar connections, right side extension box, bottom cable entry - NEMA standard hole pattern
    • High Voltage: Form wound - Permanent magnet - Winding temperature detectors - Anti Condensation Space Heater - Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
    Governing System
    • ADEM A3
    Literature
    • English
    Lubrication System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cool
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
    Mounting System
    • Rails - engine / generator / radiator mounting
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts (shipped loose)
    Starting System
    • 24 Volt electric starting motor
    • 45 Amp charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch

    Optional Equipment

    Control System
    • EMCP 4.3, EMCP 4.4
    Air Inlet System
    • Single element filter
    • Dual element air cleaner
    Cooling System
    • Standard ambient radiators
    • Air inlet protection including air shut off magnetic switch
    • Standard ambient ATAAC radiators
    • Optional installed radiator
    • Optional installed ATAAC radiators
    • Water level switch gauges
    • Coolant
    Exhaust System
    • Elbows
    • Flange and exhaust expanders
    • Flanges
    • Flexible fittings
    • Y adapters
    • Mufflers
    • Exhaust Offset
    • Clean emission parets
    Fuel System
    • Primary fuel filter
    General
    • US aid emblem
    • Special paint
    Generators and Attachments
    • 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, IE, No. of leads: 6, Picth: 0.6667 - 1600 Frame
    • 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 Frame
    • 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 and 1800 Frames
    • Space heater
    • Generator conversions IE to PM
    • Alternator air cleaner
    Intrumentation
    • Pyrometer and thermocouples
    Lube System
    • Lube oil
    • Oil lever regulator
    • Prelube pump groups
    Crankcase Systems
    • Crankcase protection group: No explosion relief valves; Explosion relief valves
    • Crankcase ventilation system
    Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
    Power Connections
    • Grounding groups
    • Neutral ground connections
    • Center post busbars
    • Right, left side and rear power connections
    Special Tests / Reports
    • CSA certification
    • IBC certification
    • Special package tests: PGS test report @ 1.0 and 0.8 power factors
    • Standard engine test charge
    • Generator set test report
    • Fuel consumption test
    • Torsional vibration analysis TVA report
    Starting / Charging Sytem
    • Jacket water heaters

    listofrelationships

    original

    original

    original

    Other Models in this Category

    Select Generator Type


    Hawthorne Power Systems Logo

    Request a Quote

    Why Cat is Better. Machine Comparison

    "
    With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
    Mark Cripe
    Helix Electric
    "

    San Diego - Power
    Phillip J. Smith (PJ)
    Field Service Manager
    858.376.6874 office
    858.688.0134 mobile
    psmith@hawthornecat.com

    Paul Karpf
    Rental Department Manager
    858.376.6888 office
    858.688.0039 mobile
    pkarpf@hawthornecat.com

    Tom Bonham
    Product Support Sales Manager
    858.376.6898 office
    442.248.2108 mobile
    tbonham@hawthornecat.com

    Hawaii – Power
    Cliff Yuen
    Power Systems Sales Manager
    808.676.0322 office
    808.349.7767 mobile
    cyuen@hawthornecat.com

    Guam – Power
    Myver Hecita
    Power Systems Rental &
    Sales Representative
    671.649.4241 office
    671.898.2740 mobile
    mhecita@hawthornecat.com

    Richard Nostratis
    Service Manager
    671.649.4212 office
    671.898.2735 mobile
    rnostratis@hawthornecat.com