Generator Set Specifications
Minimum Rating230 kVA
Maximum Rating330 kVA
Voltage220-480 Volts
Frequency50 Hz
Speed1500 RPM
Generator Set Configurations
Emissions/Fuel StrategyEU Stage IIIA, Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use only ( Tier 3 Nonroad Equivalent Emission Standards)
Engine Specifications
Engine ModelC9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Compression Ratio16.1:1
AspirationAir to Air Aftercooled
Governor TypeAdem™A4
Fuel SystemHydraulic electronic unit injection
Bore4.41 in
Displacement537.01 in³
Stroke5.87 in

The Generators Used On Cat Packages Have Been Designed And Tested To Work With The Cat Engine. The Generators Are Built With Robust Class H Insulation And Provide Industry Leading Motor Starting Capability. They Provide High Efficiency In A Majority Of Applications And Optional Coastal Protection For The Windings Is Available For Harsh Environments.

  • 18331028

Cat® Generator Set Packages Have Been Fully Prototype Tested, And Certified Torsional Vibration Analysis Reports Are Available. The Packages Are Designed To Meet The Nfpa 110 Requirement For Loading, And Conform To The Iso 8528-5 Steady State And Transient Response Requirements.

The Emcp Controller Features The Reliability And Durability You Have Come To Expect From Your Cat Equipment. Emcp4 Is A Scalable Control Platform Designed To Ensure Reliable Generator Set Operation, Providing Extensive Information About Power Output And Engine Operation. Emcp4 Systems Can Be Further Customized To Meet Your Needs Through Programming And Expansion Modules.

The Cooling System Has Been Designed To Operate In Standard Ambient Temperatures Up To 50°c (122°f) With An Air Flow Restriction Of 0.5 In Water. The Factory Installed Cooling System Has Been Designed And Tested To Ensure Proper Generator Set Cooling, And Includes The Radiator, Fan, Belts, And All Guarding Installed As Standard. Contact Your Cat Dealer For Specific Ambient And Altitude Capabilities.

The Generator Set Meets Transient Response And Block Loading Steps As Per Iso 8528-5.

Fully Prototype Tested With Certified Torsional Vibration Analysis Available

Cat Dealers Provide Extensive Post-sale Support Including Maintenance And Repair Agreements. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries. The Caterpillar S•o•s℠ Program Cost Effectively Detects Internal Engine Component Condition, Even The Presence Of Unwanted Fluids And Combustion By-products

Standard Equipment

Air Inlet System
  • Air cleaner, light duty with disposable paper filter
Control Panels
  • EMCP4.2 control panel
Cooling System
  • Radiator and cooling fan with guard
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
Exhaust System
  • Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use; shipped loose
Fuel System
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank
Generators and Generator Attachments
  • 12 leads
  • IP23 protection
  • Voltage regulator (single phase sensing)
  • Power centre, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory option circuit breaker, IEC, 3 pole mounted in powercentre
Governing System
  • Cat electronic governor (ADEM A4)
Lube System
  • Oil cooler
  • Lubricating oil
  • Oil drain valves
Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
  • 24V battery with rack and cables
General
  • Engine and alternator re-paint, Caterpillar Yellow

Optional Equipment

Certifications
  • European certificate for conformance
  • Global certificate fpr CIS
Air inlet system
  • Single element air cleaner
Circuit Breakers
  • 4 Pole (IEC-100% rated) circuit breaker upgrades: 400, 630, 800 and 100 amps
Control Panels
  • Control panel Options: Volt free contacts ; Local alarm horn ; Oil temperature displays
  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
Cooling System
  • Radiator duct flange
  • Low coolant temperature alarm
Enclosures
  • Sound attenuated enclosure
  • High ambient sound attenuated enclosure
Exhaust System
  • Mufflers - End in / End out; 10 dBA or 25 dBA attenuation
  • 5 - 6 inch flange adaptor
  • 6 inch flange
  • 5 and 6 inch elbow kits
Fuel System
  • Integral duel wall fuel tank base
Generators and Attachments
  • Permanent magnet generator
  • Oversize, AREP, CIP generators
Mounting System
  • Narrow skid base
Starting / Charging System
  • 5 Amp single battery charger
  • Battery disconnet switch
  • Jacket water heater

listofrelationships

original

original

Other Models in this Category

Select Generator Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Steve Jamison
Power Systems Sales Manager
858.376.6821 office
858.688.0083 mobile
sjamison@hawthornecat.com

Phillip J. Smith (PJ)
Field Service Manager
858.376.6874 office
858.688.0134 mobile
psmith@hawthornecat.com

Paul Karpf
Rental Department Manager
858.376.6888 office
858.688.0039 mobile
pkarpf@hawthornecat.com

Tom Bonham
Product Support Sales Manager
858.376.6898 office
442.248.2108 mobile
tbonham@hawthornecat.com

Hawaii – Power
Cliff Yuen
Power Systems Sales Manager
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com

Richard Nostratis
Service Manager
671.649.4212 office
671.898.2735 mobile
rnostratis@hawthornecat.com