New | C15 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Minimum Rating365 kVA
Maximum Rating550 kVA
Voltage208 to 600 Volts
Frequency50 Hz
Speed1500 RPM
Generator Set Configurations
Emissions/Fuel StrategyLow Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
Engine Specifications
Engine ModelC15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Compression Ratio16.1:1
AspirationAir to Air Aftercooled
Governor TypeAdem™A4
Fuel SystemMEUI
Bore5.4 in
Displacement927.56 in³
Stroke6.75 in

  • seismic Certification Available.
  • anchoring Details Are Site Specific, And Are Dependent On Many Factors Such As Generator Set Size, Weight, And Concrete Strength.
  • ibc Certification Requires That The Anchoring System Used Is Reviewed And Approved By A Professional Engineer
  • seismic Certification Per Applicable Building Codes: Ibc 2000, Ibc 2003, Ibc 2006, Ibc 2009, Cbc 2007, Cbc 2010
  • pre-approved By Oshpd And Carries An Osp-0321-10 For Use In Healthcare Projects In California
  • Standard Equipment

    Air Inlet
    • Air Cleaner
    Cooling
    • Package mounted radiator
    Exhaust
    • Exhaust flange outlet
    Fuel
    • Primary fuel filter with integral water separator
    • Secondary fuel filter
    • Fuel priming pump
    Generator
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • IP23 Protection
    Power Termination
    • Bus Bar
    Control Panel
    • EMCP 4 Genset Controller
    Mounting
    • Rubber vibration isolators
    Starting/Charging
    • 24 volt starting motor
    • Batteries
    General
    • Paint - Caterpillar Yellow except rails and radiators gloss black

    Optional Equipment

    Exhaust
    • Industrial, Residential, Critical Mufflers
    Generator
    • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
    • Anti-condensation heater
    • Oversize and premium generators
    Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
    Control Panels
    • EMCP (4.2) (4.3) (4.4)
    • Local & remote annunciator modules
    • Load share module
    • Digital I/O module
    • Remote monitoring software
    Starting/Charging
    • Battery chargers
    • Oversize batteries
    • Jacket water heater
    • Heavy-duty starting system
    • Charging alternator
    General
    • The following options are based on regional and product configuration:
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • UL 2200 package
    • EU Certificate of Conformance (CE)
    • CSA Certification
    • EEC Declaration of Conformity
    • Narrow, Wide or Skid Base
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Single or dual wall integral fuel tanks
    • Single or dual wall sub-base fuel tanks
    • Integral & sub-base UL listed dual wall fuel tanks
    • Automatic transfer switches (ATS)
    Enclosures
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
    Exhaust System
    • Engine mounted muffler
    • 10 dBA attenuation muffler
    • 25 dBA attenuation muffler
    • 35 dBA attenuation muffler
    • Manifold and turbo guard
    Fuel Storage System
    • Integral dual wall fuel tank base
    Fuel System
    • Manual fuel transfer pump
    • Fuel transfer system controls
    Generator Attachments
    • IP23 cover plate
    • Permanent magnet generator
    • Space heaters
    Optional Generators
    • A Frame CIP generator
    • LC Frame
    • LC CIP generator
    Lube System
    • Manual sump pump
    Mounting System
    • Narrow skid base
    Starting / Charging System
    • 5 Amp battery charger
    • Battery disconnect switch
    • Jacket water heater

    listofrelationships

    original

    original

    Other Models in this Category

    Select Generator Type


    Hawthorne Power Systems Logo

    Request a Quote

    Why Cat is Better. Machine Comparison

    "
    With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
    Mark Cripe
    Helix Electric
    "

    San Diego - Power
    Steve Jamison
    Power Systems Sales Manager
    858.376.6821 office
    858.688.0083 mobile
    sjamison@hawthornecat.com

    Phillip J. Smith (PJ)
    Service Manager - CSA Group
    858.376.6874 office
    858.688.0134 mobile
    psmith@hawthornecat.com

    Paul Karpf
    Rental Department Manager
    858.376.6888 office
    858.688.0039 mobile
    pkarpf@hawthornecat.com

    Tom Bonham
    Product Support Sales Manager
    858.376.6898 office
    442.248.2108 mobile
    tbonham@hawthornecat.com

    Hawaii – Power
    Cliff Yuen
    Power Systems Sales Manager
    808.676.0322 office
    808.349.7767 mobile
    cyuen@hawthornecat.com

    Guam – Power
    Myver Hecita
    Power Systems Rental &
    Sales Representative
    671.649.4241 office
    671.898.2740 mobile
    mhecita@hawthornecat.com

    Richard Nostratis
    Service Manager
    671.649.4212 office
    671.898.2735 mobile
    rnostratis@hawthornecat.com