Generator Set Specifications
Minimum Rating680 ekW
Maximum Rating800 ekW
Voltage208 to 600
Frequency60 Hz
Speed1800 RPM
Generator Set Configurations
Emissions/Fuel StrategyLow Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
Engine Specifications
Engine ModelC27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel
Bore5.4 in
Displacement1649.47 in³
Stroke6 in
Compression Ratio16.5:1
AspirationTA
Governor TypeAdem™A4
Fuel SystemMEUI

  • reliable, Rugged, Durable Design
  • field-proven In Thousands Of Applications Worldwide
  • four-stroke-cycle Diesel Engine Combines Consistent Performance And Excellent Fuel Economy With Minimum Weight
  • matched To The Performance And Output Characteristics Of Cat Engines
  • industry Leading Mechanical And Electrical Design
  • industry Leading Motor Starting Capabilities
  • high Efficiency
  • The Emcp Controller Features The Reliability And Durability You Have Come To Expect From Your Cat Equipment. Emcp4 Is A Scalable Control Platform Designed To Ensure Reliable Generator Set Operation, Providing Extensive Information About Power Output And Engine Operation. Emcp4 Systems Can Be Further Customized To Meet Your Needs Through Programming And Expansion Modules.

  • seismic Certification Available.
  • anchoring Details Are Site Specific, And Are Dependent On Many Factors Such As Generator Set Size, Weight, And Concrete Strength.
  • ibc Certification Requires That The Anchoring System Used Is Reviewed And Approved By A Professional Engineer
  • seismic Certification Per Applicable Building Codes: Ibc 2000, Ibc 2003, Ibc 2006, Ibc 2009, Cbc 2007, Cbc 2010
  • pre-approved By Oshpd And Carries An Osp-0321-10 For Use In Healthcare Projects In California
  • The Generator Set Accepts 100% Rated Load In One Step Per Nfpa 110 And Meets Iso 8528-5 Transient Response.

  • ul 2200 Listed Packages
  • Csa Certified
  • certain Restrictions May Apply.
  • Consult With Your Cat® Dealer.
  • Fully Prototype Tested With Certified Torsional Vibration Analysis Available

    Cat Dealers Provide Extensive Post-sale Support Including Maintenance And Repair Agreements. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries. The Caterpillar S•o•s℠ Program Cost Effectively Detects Internal Engine Component Condition, Even The Presence Of Unwanted Fluids And Combustion By-products

    Standard Equipment

    Air Inlet
    • Air Cleaner; single element canister type with service indicator
    Control Panel
    • EMCP 4 / EMCP 4.2B Genset Controllers
    • EMCP 4.2B Control Features
    • Digital Indicators
    • Warning/shutdown Indicators
    • Programmable Protective Relaying Functions
    • Communications
    Cooling
    • ATAAC
    • Radiator sized to 50 degrees C
    • Coolant drain line with valve terminated on edge of base
    • Fan and belt guards drive
    • Coolant level sensor
    • Caterpillar Extended Life Coolant
    Exhaust
    • Exhaust Manifold - dry
    • 203mm (8in) ID round flanged outlet
    Fuel
    • Primary fuel filter with integral water separator
    • Secondary fuel filter
    • Fuel cooler
    • Flexible fuel lines - installed
    • Electric fuel priming pump
    Generators and Attachments
    • SR5 Permanent Magnet (PM)
    • For EPA Stationary Emergency (EPA Tier 2 Emissions) configurations02/11/2017:
    • For Low BSFC configurations:
    • Integrated Voltage Regulator (IVR) includes
    • Bus bar connections:
    Lube System
    • Lubricating oil
    • Standard volume oil pan - 68 Ltr
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal - open crankcase ventilation routed to front of package
    Mounting System
    • Rails - engine/generator/radiator mounting
    • Rubber anti-vibration mounts - shipped loose
    Starting and Charging System
    • 24-volt electric starting motor
    • Charging Alternator 45A
    • Battery, rack and cables - shipped-loose
    • Battery disconnect switch
    General
    • Paint: Caterpillar Yellow with high gloss black rails & radiator
    • RH Service
    • Flywheel and flywheel housing-SAE No. 0 and SAE No. 18
    • SAE Standard Rotation

    Optional Equipment

    Air Inlet System
    • Standard air cleaners
    • Dual element air cleaners
    • Heavy duty air cleaners
    Starting / Charging System
    • 10 Amp battery chargers
    • 20 Amp enclosure battery chargers
    • 24 Volt battery sets - Dry
    • 24 Volt electric start motors - Heavy duty
    • Jacket water heaters
    • Air starting motor with control and silencer
    • Space heater
    Circuit Breakers
    • 400, 800, 1200, 1600, 2000, 2500, 3000 Amp, 3 pole, UL-100% rated circuit breakers
    • 2000 Amp, 3 pole, IEC rated circuit breakers
    • 800 Amp, 4 pole, IEC rated circuit breakers
    Control Panels
    • EMCP (4.2B) (4.3) (4.4)
    • Remote mounting harness
    • Remote mounted circuit breaker terminals
    • Remote mounted panel harness mounting kit
    • Auxiliary box options
    • Side extension box
    • Cable shroud - Top mounted
    • Cable shroud - Bottom mounted
    • Cat connect telematics
    • Installed DIO module
    • Remote DIO module
    • Annunciator modules
    • Remote annunciator modules
    • Modbus monitor local packages
    • Load share module
    • Vandal proof panel cover
    Cooling System
    • Standard radiator
    • High ambient radiator
    • Certified radiator
    • Extended life coolant
    • Radiator duct flange
    Enclosures
    • Special sound attenuated enclosure
    • Enclosure with lifting base or fuel tank
    • Enclosure fuel tank options
    • Enclosure louvers
    • Cold weather bundle
    • Enclosure lighting
    • AC distribution panel, lights and outlet
    • Panel bracket
    • Enclosure colors
    Exhaust System
    • Flanges
    • Guard and shield system
    • Elbows
    • Flexible fittings
    • Mufflers
    • Exhaust through the wall kit
    Generator and Attachments
    • 60 Hz standard generators
    • 60 Hz premium generators
    Lube System
    • Oil level regulator
    • Prelube pumps
    Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
    • Mounting base type
    Power Connections
    • Neutral grounding connection
    • Center post busbar
    • Power connections - Right / Left / Rear
    • Cable entry - Right / Left / Rear
    Special Tests / Reports
    • IBC Seismic certifications
    • OSHPD Seismic certifications
    • Special CSA test cerification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Generator test report
    • Standard engine test
    • Torsional vibration analysis report
    General
    • Special paint
    • US aid emblem
    • SGS Inspection
    • Miscellaneous inspection

    listofrelationships

    small_image

    Other Models in this Category

    Select Generator Type


    Hawthorne Power Systems Logo

    Request a Quote

    Why Cat is Better. Machine Comparison

    "
    With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
    Mark Cripe
    Helix Electric
    "

    San Diego - Power
    Steve Jamison
    Power Systems Sales Manager
    858.376.6821 office
    858.688.0083 mobile
    sjamison@hawthornecat.com

    Phillip J. Smith (PJ)
    Service Manager - CSA Group
    858.376.6874 office
    858.688.0134 mobile
    psmith@hawthornecat.com

    Paul Karpf
    Rental Department Manager
    858.376.6888 office
    858.688.0039 mobile
    pkarpf@hawthornecat.com

    Tom Bonham
    Product Support Sales Manager
    858.376.6898 office
    442.248.2108 mobile
    tbonham@hawthornecat.com

    Hawaii – Power
    Cliff Yuen
    Power Systems Sales Manager
    808.676.0322 office
    808.349.7767 mobile
    cyuen@hawthornecat.com

    Travis Tilton
    General Service Manager
    808.676.0314 office
    808.864.1903 mobile
    ttilton@hawthornecat.com

    Guam – Power
    Myver Hecita
    Power Systems Rental &
    Sales Representative
    671.649.4241 office
    671.898.2740 mobile
    mhecita@hawthornecat.com

    Richard Nostratis
    Service Manager
    671.649.4212 office
    671.898.2735 mobile
    rnostratis@hawthornecat.com