Generator Set Specifications
Minimum Rating1750 kVA
Maximum Rating2500 kVA
Voltage220 to 13800
Frequency50 Hz
Speed1500 RPM
Generator Set Configurations
Emissions/Fuel StrategyLow Fuel Consumption, Low Emissions
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Compression Ratio14.0:1 Std 15.5:1 HD
AspirationTA
Governor TypeAdem™3
Fuel SystemElectronic unit injection
Bore6.69 in
Displacement - HD4764.73 in³
Displacement - Std4210.64 in³
Stroke - HD8.46 in
Stroke - Standard7.48 in

Standard Equipment

Air Inlet System
  • Air Cleaner; single element canister type
Control Panels
  • EMCP4
  • Emergency stop pushbutton
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm/event descriptions
  • Generator mounted - rear facing
  • Generator set packages include Caterpillar' s Voltage Regulator . IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for: RPM - DC volts - Operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - k
  • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
  • Programmable protective relaying functions: Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kW) (32) - Reverse Reactive Power (kVAr) (32RV) - Overcurrent (50/51)
  • Communications: Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Cat Connect - 3 Analog inputs - 6 Customer programmable digital inputs
  • Number of I/O varies on options selected: 4 programmable relay outputs (Form A) - 1 programmable relay outputs (Form C) - 1 programmable digital outputs
Cooling System
  • Certified standard PGS provided
  • ATAAC - 3516E Package Radiators shipped installed
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
Fuel System
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
General
  • Caterpillar yellow with high gloss black rails and radiator
  • Right hand servicing
  • Flywheel and flywheel housing - SAE No. 00
  • SAE Standard rotation
Generator and Attachments
  • 3 Phase brushless, salient pole
  • 6 lead
  • Low Voltage: Random wound - Internal Excitation - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pa
  • Medium Voltage: Form wound - Permanent magnet - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Bus bar connections, right side extension box, bottom cable entry - NEMA standard
  • High Voltage: Form wound - Permanent magnet - Winding temperature detectors - Anti Condensation Space Heater - Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
Governing System
  • ADEM A3
Literature
  • English
Lubrication System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cool
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
Mounting System
  • Rails - engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts (shipped loose)
Starting System
  • 24 Volt electric starting motor
  • 45 Amp charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch

Optional Equipment

Control System
  • EMCP4.2B, EMCP4.3 and EMCB4.4
Air Inlet System
  • Single element filter
  • Dual element air cleaner
Cooling System
  • Standard ambient radiators
  • Standard ambient ATAAC radiators
  • Optional installed radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Coolant
Crankcase System
  • No explosion relief valves
  • Explosion relief valves
  • Ventilation system
Exhaust System
  • Elbows
  • Flange and exhaust expanders
  • Flanges
  • Flexible fittings
  • Y-Adapters
  • Mufflers
  • Exhaust offset
  • Tier 4 clean emissions module
  • Tier 4 dosing cabinet
  • Tier 4 clean emission MOD Kits
  • Clean emission parts
Fuel System
  • Primary Fuel Filter
  • Fuel Priming Pumps (Tier 4) - Manual or Electric
General
  • US aid emblem
  • Special paint (Colors other than Caterpillar yellow or high performance paints)
Generators and Attachments
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Space heater
  • Generator conversion
  • Thermostate for space heater
  • Alternator air cleaner
  • Differential current transformers (DCT)
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
Instrumentation
  • Pyrometer and Thermocouples
Lubrication System
  • Lube oil in standard sump
  • Oil level regulator
  • Prelube pumps
Mounting System
  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators
Power Connections
  • Ground cables between generator and terminal box
  • Neutral ground connections
  • Center post busbar
  • Right side power connections
  • Left side power connections
  • Rear power connections
  • 2700 Frame, four lead, four terminal
  • Low voltage circuit breakers
Special Tests / Reports
  • Canadian Standards Association certification
  • IBC certification
  • OSHPD certification
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Standard engine test charge
  • generator test report
  • Fuel consumption test
  • Generator set fuel consumption test
  • Torsional vibration analysis reports
Starting and Charging
  • Engine barring device
  • 24 Volt battery set - Dry
  • 10, 20, 35 and 50 amp battery chargers
  • Electric starting motors
  • Air starting motors
  • Starter cover
  • Air pressure regulator
  • Jacket water heaters
Extended Service Coverage
  • Platinum, Gold and Silver coverage

listofrelationships

original

Other Models in this Category

Select Generator Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Steve Jamison
Power Systems Sales Manager
858.376.6821 office
858.688.0083 mobile
sjamison@hawthornecat.com

Phillip J. Smith (PJ)
Service Manager - CSA Group
858.376.6874 office
858.688.0134 mobile
psmith@hawthornecat.com

Paul Karpf
Rental Department Manager
858.376.6888 office
858.688.0039 mobile
pkarpf@hawthornecat.com

Tom Bonham
Product Support Sales Manager
858.376.6898 office
442.248.2108 mobile
tbonham@hawthornecat.com

Hawaii – Power
Cliff Yuen
Power Systems Sales Manager
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com

Richard Nostratis
Service Manager
671.649.4212 office
671.898.2735 mobile
rnostratis@hawthornecat.com