New | C4.4 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Minimum Rating36 ekW
Maximum Rating100 ekW
Voltage220-480 Volts
Frequency60 Hz
Speed1800 RPM
Generator Set Configurations
Emissions/Fuel StrategyNon Regulated, EU Stage II
Engine Specifications
Engine ModelC4.4, In-line 4, 4-cycle diesel
Compression Ratio18.2:1
Governor TypeAdem™A4
Fuel SystemElectronic (adjustable)
Bore4.13 in
Displacement268.5 in
Stroke5 in

  • The Generator Set Is Designed To Meet Iso8528-5 Transient Response And Nfpa 110.
  • Cooling System Designed To Operate In 50˚c / 122˚f Ambient Temperatures With An Air Flow Restriction Of 0.5 In. Water.
  • Fully Prototype Tested With Certified Torsional Vibration Analysis Available

    Ce Certification Available

    Cat Dealers Provide Extensive Post-sale Support Including Maintenance And Repair Agreements. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries. The Caterpillar S•o•s℠ Program Cost Effectively Detects Internal Engine Component Condition, Even The Presence Of Unwanted Fluids And Combustion By-products

  • single Wall 8 Hour Wide Fuel Tank
  • circuit Breaker, Iec, 3 Pole
  • industrial Silencer (10dba)
  • Standard Equipment

    Air Inlet System
    • Air cleaner; light duty with disposable element
    Control Panel
    • EMCP4.1
    Cooling System
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar Extended Life Coolant
    Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
    Fuel System
    • Standard Open set Fuel tank / base supplied Base, formed steel with single wall integral 8-hour fuel tank
    Generators and Attachments
    • 12 leads
    • IP23 Protection
    • Voltage Regulator (single phase sensing)
    • Tower Panel, IP22, bottom cable entry
    • Segregated low voltage (AC/DC) wiring panel
    • Circuit breaker, IEC, 3 pole, mounted in Tower Panel
    Governing System
    • Mechanical and electrical governing system - model dependant
    Lube System
    • Lubricating oil
    • Oil drain line with valve
    Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
    Starting/Charging
    • 12V Battery with rack & cables
    General
    • Engine and alternator pre-paint, Caterpillar yellow

    Optional Equipment

    Alternator System
    • R frame auxilliary winding
    • Optional LC frame alternator
    • Optional LC frame alternator with coastal insulation protection
    • Permanent magnet
    • 3 Phase sensing
    • Quadrature droop kit
    • Anti-condensation heater
    Certifications
    • Global certification for CIS
    • European certificate for upgrade to STD for CE
    Circuit Breakers
    • 4 Pole Circuit breaker upgrades to 250A, 400A and 630A
    • Pad-lockable breaker device
    Control Panels
    • EMCP 4.2
    • Volt free contacts
    • Speed adjust potentiometer
    • Voltage adjust potentiometer
    • Panel mounted audible alarm
    • Earth fault (2 wire only)
    • Earth leakage (2 wire only)
    • Overload shutdown via breaker
    • Battery charger
    • Emergency stop with key
    • Control panel heater
    Cooling System
    • Coolant heater
    • Low coolant temperature alarm
    • Low coolant level shutdown
    Enclosures
    • Sound attenuated level 2 enclosure
    • sount attenuated level 1 enclosure (galvanised)
    • Rental pack (CAE only)
    Fuel System
    • Open set narrow tankbase
    • Compact skidbase for open sets
    • Skidbase for CALG enclosure sets
    • Bunded fuel tank
    • Low fuel level shutdown
    • Low fuel level alarm
    • High fuel level alarm
    Mounting Options
    • Electronic governor
    • Battery removal
    • External single point lift - enclosure
    • Residential silencer
    • Silencer installation kit
    General
    • Stone guards / rad trans flange

    listofrelationships

    original

    original

    Other Models in this Category

    Select Generator Type


    Hawthorne Power Systems Logo

    Request a Quote

    Why Cat is Better. Machine Comparison

    "
    With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
    Mark Cripe
    Helix Electric
    "

    San Diego - Power
    Steve Jamison
    Power Systems Sales Manager
    858.376.6821 office
    858.688.0083 mobile
    sjamison@hawthornecat.com

    Phillip J. Smith (PJ)
    Field Service Manager
    858.376.6874 office
    858.688.0134 mobile
    psmith@hawthornecat.com

    Paul Karpf
    Rental Department Manager
    858.376.6888 office
    858.688.0039 mobile
    pkarpf@hawthornecat.com

    Tom Bonham
    Product Support Sales Manager
    858.376.6898 office
    442.248.2108 mobile
    tbonham@hawthornecat.com

    Hawaii – Power
    Cliff Yuen
    Power Systems Sales Manager
    808.676.0322 office
    808.349.7767 mobile
    cyuen@hawthornecat.com

    Guam – Power
    Myver Hecita
    Power Systems Rental &
    Sales Representative
    671.649.4241 office
    671.898.2740 mobile
    mhecita@hawthornecat.com

    Richard Nostratis
    Service Manager
    671.649.4212 office
    671.898.2735 mobile
    rnostratis@hawthornecat.com