New | MX150 Microprocessor Controller

The MX150 microprocessor is standard with the CTG product family. The MX150 microprocessor panel controls the operation and displays thes tatus of the transfer switch’s position, timer sand available sources. As an embedded digital controller, the MX series offers high reliability and ease of unattended operation across a range of applications.

Technical Summary
Rating RangeSwitch Dependent
Transfer TypeApplication Dependent
Switch TypeApplication Dependent
Controller Specifications
Undervoltage dropout for source 1 and source 275-98% of nominal
Undervoltage restore for source 1 and source 285-100% of nominal
Underfrequency dropout for source 1 and source 288-98% of nominal
Underfrequency restore for source 1 and source 290-100% of nominal
Delay for engine cool down (U)0-10 seconds
Delay transfer to nonpreferred source (W)0-5 minutes
Delay NeutralTransition time delays (DT,DW)0-10 minutes
Storage temperature(-30˚C - 75˚C ), -22˚F - 167˚F
Operating temperature (ambient)40 - 400 amp molded shell (-20˚C to 65˚C) , -4˚F to 149˚F
40 - 4000 amp all others (-20˚C to 60˚C), -4˚F to 149˚F

  • digital Timer And Adjustments With 1 Second Resolution
  • long Lasting Led Indicators And An Easy-to-view Lcd Display
  • inputs Optoisolated For High Electrical Immunity To Transients And Noise
  • digital Voltage And Frequency Adjustments With1% Resolution
  • voltage And Frequency Sensing Includes:
    –voltage Imbalance Detection Between Phases
    –under Frequency Sensing On Source 2
    –3 Phase Under Voltage Sensing On Source 1(s1)
    – Normal And Single Phase Sensing Onsource (s2)
    – Emergency
  • modular Pre-signal Option Easily Integrated Into The System (e.g. Elevator Pre-signal And Motor Load Disconnect)
  • universal Motor Disconnect (umd) Available For Programming To Pre-signal, Post-signal Or Both
  • line Voltage Transients Are Isolated From The Control Board Using Remote Transformers
  • simplified Major Components And Modules For Easy Replacement
  • on-board Diagnostics Including Voltage Frequency, Control And Timing
  • nonvolatile Memory – Battery Backup Not Required During Normal Source Outage
  • external Communication Available Through Lonworks/modbus Network Interface (rs232,rs 422, And Rs 485 Are Also Available)
  • maintained And Momentary Test Positions Are Available To The Controller
  • test Mode Allows Manual Bypass Of All Transfer Timers When Applicable
  • automatic Daylight Savings Adjustment Available

  • leds For Continuous Monitoring Of Switch Position, Source Availability, Exercise Time Delay Operation And Diagnostics
  • simplified Adjustment For Voltage, Frequency And Time Delay Settings
  • close Differential 3 Phase Under-voltage Sensing Of Source 1, Factory Standard Setting 90% Pickup,80% Dropout (adjustable); Under-frequency Sensing Of The Source 1 Factory Setting 95% Pickup (adjustable)
  • voltage And Frequency Sensing Of Source 2,factory Standard Setting 90% Pickup Voltage,95% Pickup Frequency (adjustable)
  • test Switch (fast Test/load/no Load) To Simulate Normal Source Failure – Automatically Bypassed Should Source 2 Fail

listofrelationships

original

Other Models in this Category

Select Integrated System Type


Hawthorne Power Systems Logo

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Steve Jamison
Power Systems Sales Manager
858.376.6821 office
858.688.0083 mobile
sjamison@hawthornecat.com

Phillip J. Smith (PJ)
Service Manager - CSA Group/Truck Shop
858.376.6874 office
858.688.0134 mobile
psmith@hawthornecat.com

Joel Gollihur
Truck Service Manager
858.376.6841 office
858.688.0084 mobile
jgollihur@hawthornecat.com

Paul Karpf
Rental Department Manager
858.376.6888 office
858.688.0039 mobile
pkarpf@hawthornecat.com

Hawaii – Power
Cliff Yuen
Power Systems Sales Manager
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Travis Tilton
General Service Manager
808.676.0314 office
808.864.1903 mobile
ttilton@hawthornecat.com

Bobby Fields
Rental Developer
808.676.0267 office
808.368.5445 mobile
bfields@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com

Jimmy Cruz
Engine Service Manager
671.649.4216 office
671.488.2821 mobile
jpcruz@hawthornecat.com