New | CTG Series Automatic Transfer Switch

The Cat® CTG Series Automatic Transfer Switches (ATS) are pre-configured for applications requiring the dependability and ease of operation found in a full feature power contactor type transfer switch.

CTG switches are equipped with the next generation MX150 microprocessor panel, which controls the operation and displays the status of the transfer switch’s position, timers and available sources. As an embedded digital controller, the MX150 offers high reliability and ease of unattended operation across a range of applications.

Technical Summary
Rating Range40-3000A
Transfer TypeOpen transition
Switch TypeContactor based

  • ratings 40 To 3000 Amps (2, 3 Or 4 Poles)
  • Ul 1008 Listed At 480 Vac
  • Csa Certified At 600 Vac (200-225 Amp – 480v)
  • Iec Listed At 480 V
  • double Throw, Mechanically Interlocked Contactor Mechanism
  • electrically Operated, Mechanically Held
  • designed For Emergency And Standby Applications
  • available In Standard Open Transition (ctg)or Delayed Transition (ctgd) Models
  • Ringing Wave Immunity Per Ieee 472 (ansi C37.90a
  • conducted And Radiated Emissions Per En55022 Class B (cispr 11) (exceeds En55011 & Milstd 461 Class 3)
  • esd Immunity Test Per En61000-4-2 (level 4)
  • radiated Rf, Electromagnetic Field Immunity Test Per En61000-4-3 (env50140) 10v/m
  • electrical Fast Transient/burst Immunity Test Per En61000-4-4
  • radiated Rf, Electromagnetic Field Immunity
  • surge Immunity Test Per En61000-4-5 Ieee C62.41 (1.2 X 50 Ms, 5 & 8 Kv)
  • conducted Immunity Test Per En61000-4-6 (env50141)
  • voltage Dips And Interruption Immunity En61000-4-11
  • seismic Compliance To Ieee-693-2005 And Ibc-2003

  • close Differential 3 Phase Under-voltage Sensing Of The Normal Source – Factory Standard Setting 90% Pickup, 80% Dropout (adjustable);under Frequency Sensing Of The Normal Source Factory Setting 95% Pickup (adjustable)
  • voltage And Frequency Sensing Of The Emergency Source – Factory Standard Setting 90% Pickup Voltage, 95% Pickup Frequency (adjustable)
  • test Switch (fast Test/load/no Load) To Simulate Normal Source Failure – Automatically Bypassed Should The Emergency Source Fail
  • type 1 Enclosure Is Standard – Also Available In Open Style Or Types 3r, 4, 4x, Or 12
  • Standard Features
    • Auxiliary Contact:
      Closed when the switch is in the emergency position
      (Additional contacts optional)
    • Auxiliary Contact:
      Closed when the switch is in the normal position
      (Additional contacts optional)
    • 7, 14, 28 day interval timed exerciser, pushbutton/timer operation
    • Engine Start Contact
    • Indicating LED Pilot Lights:
      -Switch in emergency position
      -Switch in normal position
      - Normal source available
      -Emergency source available
    • Time Delay to Engine Start: Standard setting 3 seconds, adjustable 0-10 seconds
    • In-Phase Monitor, self-adjusting (Not available on CTGD models)
    • Time Delay on Retransfer to Normal: To delay retransfer to normal source (immediate retransfer on generator set failure); standard setting 30 minutes, adjustable 0-60 minutes
    • Push button Bypass of time delay and normal emergency
    • Test Switch – Momentary
    • Event Log OD 16 Event that track date, time, reason and action taken
    • Voltage and Frequency Indication for S1 and S2
    • Peak Shave/Remote Load Test: Input for peak shave or remote load test; includes automatic return to normal if emergency source fails and normal is present; 120 VAC
    • When specified for use with a CTGD Series delayed transition switch, the control panel also includes the following:
    MX150 Control Panel
    • Time Delay for Engine Cool Down: Allows engine to run unloaded after switch retransfer to normal; standard setting 5 minutes, adjustable 0-60 minutes
    • Time Delay on Transfer to Emergency: To delay transfer to emergency after verifying emergency source available; standard setting 1 second, adjustable 0-5 minutes
    • Timer and voltage/frequency settings adjustable without disconnection from power sources
    • Built-in diagnostics with LCD display for immediate troubleshooting
    • LED/LCD indicators for ease of viewing and long life
    • Nonvolatile memory (exerciser battery backup not required for standard operation)
    • Processor and digital circuitry isolated from line voltage
    • Inputs opto-isolated for high electrical immunity to transients and noise
    • Communications header for network interface



    Other Models in this Category

    Select Integrated System Type

    Hawthorne Power Systems Logo

    Why Cat is Better. Machine Comparison

    With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
    Mark Cripe
    Helix Electric

    San Diego - Power
    Steve Jamison
    Power Systems Sales Manager
    858.376.6821 office
    858.688.0083 mobile

    Phillip J. Smith (PJ)
    Service Manager - CSA Group/Truck Shop
    858.376.6874 office
    858.688.0134 mobile

    Dan Hixon
    Field Service Manager
    858.376.6822 office
    858.663.4652 mobile

    Paul Karpf
    Rental Department Manager
    858.376.6888 office
    858.688.0039 mobile

    Tom Bonham
    Product Support Sales &
    Advanced Electrical Services Manager
    858.376.6898 office
    442.248.2108 mobile

    Hawaii – Power
    Cliff Yuen
    Power Systems Sales Manager
    808.676.0322 office
    808.349.7767 mobile

    Travis Tilton
    General Service Manager
    808.676.0314 office
    808.864.1903 mobile

    Bobby Fields
    Rental Developer
    808.676.0267 office
    808.368.5445 mobile

    Guam – Power
    Myver Hecita
    Power Systems Rental &
    Sales Representative
    671.649.4241 office
    671.898.2740 mobile

    Jimmy Cruz
    Engine Service Manager
    671.649.4216 office
    671.488.2821 mobile