Generator Set Specifications
Minimum Rating1750 kVA
Maximum Rating2275 kVA
Voltage220 to 11000
Frequency50 Hz
Speed1500 RPM
Generator Set Configurations
Emissions/Fuel StrategyLow Fuel Consumption
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Compression Ratio14.0:1 Std 15.5:1 HD
AspirationTA
Governor TypeAdem™4
Fuel SystemElectronic unit injection
Bore6.69 in
Displacement - HD4764.73 in³
Displacement - Std4210.64 in³
Stroke - HD8.46 in
Stroke - Standard7.48 in

Cat Generator Set Packages Have Been Fully Prototype Tested, And Certified Torsional Vibration Analysis Reports Are Available. The Packages Are Designed To Accept 100% Load In One Step, Meet The Nfpa 110 Requirement For Loading, And Conform To The Iso 8528-5 Steady State And Transient Response Requirements

The Four Cycle Cat Diesel Engine Combines Consistent Performance With Excellent Fuel Economy And Transient Response That Meets Or Exceeds Iso 8528-5. The Engines Have Been Designed And Built For A Wide Range Of Applications And Can Be Optimized For Low Fuel Consumption Or Low Emissions. The Engines Feature A Reliable, Rugged, And Durable Design That Has Been Field Proven In Thousands Of Applications Worldwide From Emergency Standby Installations To Continuously Operating Power Plants.

The Cooling System Has Been Designed To Operate In Standard Ambient Temperatures Up To 50°c (122°f), With Optional High Ambient Radiators Available. The Factory Installed Cooling System Has Been Designed And Tested To Ensure Proper Generator Set Cooling, And Includes The Radiator, Fan, Belts, And All Guarding Installed As Standard. Contact Your Cat Dealer For Specific Ambient And Altitude Capabilities.

The Generators Used On Cat Packages Have Been Designed And Tested To Work With The Cat Engine. The Generators Are Built With Robust Class H Insulation And Provide Industry Leading Motor Starting Capability. Random Wound Generators Provide Good Generator Performance In A Majority Of Applications And Form Wound Is Available For Harsh Mechanical And Electrical Environments.

The Emcp Controller Features The Reliability And Durability You Have Come To Expect From Your Cat Equipment. Emcp4 Is A Scalable Control Platform Designed To Ensure Reliable Generator Set Operation, Providing Extensive Information About Power Output And Engine Operation. Emcp4 Systems Can Be Further Customized To Meet Your Needs Through Programming And Expansion Modules.

Cat Dealers Provide Extensive Post Sale Support Including Maintenance And Repair Agreements. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries. The Caterpillar S•o•s℠ Program Cost Effectively Detects Internal Engine Component Condition, Even The Presence Of Unwanted Fluids And Combustion By-products.

Standard Equipment

Air Inlet System
  • Air cleaner, single element canister type
Control System
  • EMCP 4.2
  • Emergency stop pushbutton
  • 24 Volt DC operation
  • Environmental sealed front face
  • Text alarm / event descriptions
  • Generator mounted - rear facing
  • Generator set packages include Caterpillars Voltage
  • Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • Limiter and exciter diode monitor
  • Controls:
  • Speed adjust
  • Auto / star t/ stop control
  • Engine cool-down timer
  • Engine cycle crank
  • Alarm acknowledge
  • Lamp test
  • Load histogram feature
  • PLC functionality
  • Customizable screens
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N), frequency (Hz)
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning / shutdown with common LED indication of shutdowns for:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Programmable protective relaying functions:
  • Generator phase sequence
  • Over / under voltage (27/59)
  • Over / under frequency (81 o/u)
  • Reverse power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Communications:
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • Cat Connect
  • 3 Analog inputs
  • 6 Customer programmable digital inputs
  • Number of I/O varies on options selected:
  • 4 Programmable relay outputs (Form A)
  • 1 Programmable relay outputs (Form C)
  • 1 Programmable digital outputs
Cooling System
  • Package mounted radiator
Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)
Fuel System
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
General
  • Paint - Caterpillar yellow except rails and radiators gloss black
  • RH Service
  • Flywheel and Flywheel housing-SAE No. 00
  • SAE Standard Rotation
Generators and Attachments
  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection
  • 3 Phase brushless, salient pole
  • 6 lead
  • LV
  • Random wound
  • Permanent magnet
  • Winding temperature detectors
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
  • MV:
  • Form wound
  • Permanent magnet
  • Winding temperature detectors
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Bus bar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
  • HV:
  • Form wound
  • Permanent magnet
  • Winding temperature detectors
  • Anti condensation space heater
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
Governing System
  • ADEM A3
Lube System
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
Mounting System
  • Rails - engine / generator / radiator mounting
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts (shipped loose)
Starting System
  • 24 Volt electric starting motor
  • 45 Amp charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch

Optional Equipment

Air Inlet System
  • Single element Filter
  • Dual element air cleaner
  • Optional radiator arrangements
  • Standard ambient radiators
  • Standard ambient ATAAC radiators
Control Panels
  • EMCP 4.3, EMCP 4.4
  • Generator main terminal box
  • Load share module
  • Digital I/O module
  • Remote monitoring software
  • Empty upper box
  • Side extension box
  • Cable Shroud
  • Annunciator - local
  • Annunciator - remote
  • Vandal proof panel cover
Cooling System
  • Water level switch gauges
  • Coolant
Crankcase Systems
  • Crankcase protection groups:
  • No explosion relief valves
  • Explosion relief valve
  • Crankcase ventilation systems
Exhaust System
  • Elbows>
  • Flange and exhaust expanders
  • Flanges
  • Flexible fittings
  • Y Adapters
  • Mufflers
  • Exhaust offset
  • Tier 4 lean emissions moduel
  • Tier 4 dosing cabinet
  • Tier 4 clean emission MOD kits
  • Clean emission parts
Extended Service Coverage
  • Platinum, Silver and Gold coverage
Fuel System
  • Primary fuel filter
  • Gas fuel filter
  • Fuel priming pump (Tier 4)
Generators and Attachments
  • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, IE, No. of leads = 6, Pitch = .6667
  • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, PM, No. of leads = 6, Pitch = .6667
  • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm ,FW, PM, No. of leads = 6, Pitch = .6667
  • 1800 Frame
  • Generators high voltage
  • 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
  • 3000 Frame - 10000, 10500, 11000 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
  • Space heater kit
  • Generator conversions
  • Hi voltage optional attachments
  • Alternator air cleaner
  • Differential current transformers
Instrumentation
  • Pyrometer and Termocouples
Lube System
  • Lube oil in standard sump
  • Oil level regulator
  • Prelube pump groups
Mounting System
  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators
Power Connections
  • Grounding groups
  • Neutral ground connections
  • Center post busbar
  • Right side power connections
  • Cable entry - right side
  • left side power connections
  • Cable entry - left side
  • Rear power connections
  • Cable entry - rear
Power Termination
  • Circuit breakers - LV packages
  • 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated circuit breakers
  • 2000, 2500, 3200 Amp, 4 Pole, IEC rated circuit breakers
  • 2000, 2500, 3200 Amp, 3 Pole, IEC rated circuit breakers
Special Tests / Reports
  • Seismic certifications
  • OSPD certification
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Standard engine test
  • Generator set report
  • Fuel consumption test
  • Torsional vibration analysis
Starting / Charging
  • Engine barring devices
  • Batteries, racks and cables
  • 10, 20 and 35 Amp battery charger
  • 50 Amp NFPA battery charger
  • Electric starting motors
  • Air starting motors
  • Starter covers
  • Air pressure regulator
  • Jacket water heaters

listofrelationships

original

Other Models in this Category

Select Generator Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Phillip J. Smith (PJ)
Field Service Manager
858.376.6874 office
858.688.0134 mobile
psmith@hawthornecat.com

Paul Karpf
Rental Department Manager
858.376.6888 office
858.688.0039 mobile
pkarpf@hawthornecat.com

Tom Bonham
Product Support Sales Manager
858.376.6898 office
442.248.2108 mobile
tbonham@hawthornecat.com

Hawaii – Power
Cliff Yuen
Power Systems Sales Manager
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com

Richard Nostratis
Service Manager
671.649.4212 office
671.898.2735 mobile
rnostratis@hawthornecat.com