Cat XLM Switchgear

DESCRIPTION

Custom Switchgear and controls are design to provide a power generation, automation and distribution system specific to electrical needs.Custom Switchgear and controls are design to provide a power generation, automation and distribution system specific to electrical needs.Electric Power

XLM Switchgear

  • High Speed Supervisory Network
  • Automatic Start/Stop
  • Automatic “Dead Bus” Coordination
  • Automatic Power Factor Control when in Parallel with Utility Power
  • Programmable Load Shed / Load Add Functions
  • Networked Engine Communications
  • Generator & Utility Protection
  • Engine Tuning
  • Mode Selection
  • Selectable Auto/ Manual Control
  • Password Protection for Protective Settings and Setup
  • Load/No Load Test
  • Touch Screen (HMI) Display
  • NFPA 99/110 Compliant Alarm
  • Annunciation with Audible Horn
  • Engine Control mimic Screen with gauges for RPM, DC Battery Voltage, Oil Pressure, Engine Coolant temperature, Engine Hours, Number of starts

  • Standard Equipment
  • Optional Equipment
  • Specs
  • Docs

Standard Equipment

Optional Equipment

Specs

Overview

Long Name:
Cat Customizable Switchgear and Controls
Name:
Cat Customizable Switchgear and Controls
Brand:
Caterpillar
Status:
Current

Technical Summary

Configuration
Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation
All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs
Application
LV and MV ( 208V - 38 kV) 50 / 60 Hz

Generator Protective Devices

ANSI Protective Devices
Per customer specification

Utility Protective Devices

ANSI Protective Devices
Per customer specification

Environmental Parameters

Certifications
Per customer specification
Control Panel Enclosure
Per customer specification
Operating Temperature
Per customer specification
Storage Temperature
Per customer specification
Low Voltage Standards
Per customer specification
Medium Voltage Standards
Per customer specification

SEE HOW Cat Customizable Switchgear and Controls COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Switchgear and Paralleling Controls
Cat Customizable Switchgear and Controls
Cat XLM Switchgear
Brand
Caterpillar
Status
Current
Configuration
Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation
All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs
Application
LV and MV ( 208V - 38 kV) 50 / 60 Hz
Operating Temperature
Per customer specification
Switchgear and Paralleling Controls
Cat Switchgear
Cat Switchgear
Brand
Caterpillar
Status
Current
Configuration
IP4X
Modes of Operation
Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc.
Application
LV 380…480 VAC, 50 Hz, 3-Phase.
Operating Temperature
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Switchgear and Paralleling Controls
Cat EGP Switchgear
Cat EGP Switchgear
Brand
Caterpillar
Status
Current
Configuration
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation
Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application
LV and MV (208V - 38 kV)
Operating Temperature
0°C to 50°C