New | C175-16 Tier 4 Final

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Minimum Rating2500 ekW
Maximum Rating3100 ekW
Emissions/Fuel StrategyU.S. EPA Certified for Non-Emergency Stationary Genset
Voltage480 to 13800 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Engine Specifications
Engine ModelC175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore6.89 in
Stroke8.66 in
Displacement5155.88 in³
Compression Ratio16:07:01
AspirationTurbo Aftercooled
Fuel SystemEUI
Governor TypeADEM™ A4
Generator Set Dimensions
Length - Minimum242.77 in
Length - Maximum312.2 in
Width - Minimum83.1 in
Width - Maximum123 in
Height - Minimum87 in
Height - Maximum142.3 in
Dry Weight - Genset (minimum)42750 lb
Dry Weight - Genset (maximum)45114 lb

  • cat Generator Set Packages Have Been Fully Prototype Tested
  • accepts 100% Block Load In One Step And Meets Other Nfpa 110 Loading Requirements
  • conform To Iso 8528-5 Steady State And Transient Response Requirements
  • reliable, Rugged, Durable Design
  • field-Proven In Thousands Of Applications Worldwide
  • four-Stroke-Cycle Diesel Engine Combines Consistent Performance And Excellent Fuel Economy With Minimum Weight
  • Sr5

  • superior Motor Starting Capability Minimizes Need For Oversizing Alternator
  • designed To Match Performance And Output Characteristics Of Cat Diesel Engines
  • robust Class H Insulation
  • user-Friendly Interface And Navigation
  • scalable System To Meet A Wide Range Of Installation Requirement
  • expansion Modules And Site-Specific Programming For Specific Customer Requirements
  • designed To Operate In Standard Ambient Temperatures Up To 50°c (122°f)
  • contact Your Cat Dealer For Specific Ambient And Altitude Capabilities
  • ul2200 Listed
  • csa Certified
  • ibc Seismic Certification
  • oshpd Pre-Approval
  • components Used In The Generator Set Are Selected Based On Seamless Design Integration To Provide The Optimum Performance
  • the Generator Set Is Fully Assembled At A Caterpillar Facility Following Our Quality Guidelines
  • each Generator Set Package Is Tested Before Leaving The Caterpillar Facility
  • cat Product Support, Including Dealer Service, Parts And Warranty Covers The Entire Cat Power System
  • cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries
  • your Local Cat Dealer Provides Extensive Post-Sale Support, Including Maintenance And Repair Agreements
  • Standard Equipment

    Control Panel
    • EMCP4.3
    • Emergency stop button
    • 24-volt DC operation
    • Environmental sealed front face
    • Text alarm / event descriptions
    • Warning / Shutdown with common LED indication of shutdowns with indicating lights for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant level (requires optional coolant sensor)
    • Generator mounted - rear facing
    • Controls:
    • Speed adjust
    • Auto/start/stop control
    • Engine cool-down timer
    • Engine cycle crank
    • Alarm acknowledge
    • Lamp test
    • True RMS AC metering, 3-phase, +/-0.25% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Coolant temperature
    • Volts (L-L & L-N)
    • Frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • kW-hr (total)
    • kVAr-hr (total)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level Over / Under voltage (27/59)
    • Over / Under frequency (81 o/u)
    • Reverse power (kW) (32)
    • Reverse reactive power (kVAr) (32RV)
    • Overcurrent (50/51)
    • Communications
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • 6 Programmable digital inputs
    • 4 Programmable relay outputs (Form A)
    • 2 Programmable relay outputs (Form C)
    • 2 Programmable digital outputs
    • 12 Programmable digital inputs
    • 16 Programmable digital outputs
    • 3 Programmable analog inputs
    • 3 Programmable analog outputs
    • 2 Programmable PWM outputs
    • Local annunciator option
    Cooling System
    • SCAC cooling
    • Radiator group shipped loose
    • Fan and belt guards
    • Coolant drain line and valves
    • Coolant sensor - (2 x shipped loose: 1/4-18 and 1/2-14 NPTF)
    Exhaust System
    • Insulated CEM
    • CEM dosing module
    • CEM dosing module features:
    • Air filter
    • DEF filter
    • 120 VAC
    • Anti-freeze protection
    • Harness from dosing module to CEM
    • Air and heated DEF lines from dosing module to CEM
    • Dry exhaust manifold
    • Flanged faced outlets at CEM in (21.2") and out (25")
    Fuel System
    • Primary fuel filter water / fuel water separator
    • 10 Micron spin on type
    • 3 Filters, shipped loose - can be mounted on frame rails (Requires dealer provided flex)
    • Secondary / tertiary fuel filters
    • 4 Micron Spin On Type
    • 3 Filters, engine mounted
    Generator and Attachments
    • 3 Phase brushless, salient pole
    • 6 Lead
    • IEC platinum stator RTDs (.00385 temperature coefficient)
    • Caterpillar's digital voltage regulator (CDVR) includes:
    • Reactive droop capability
    • 3-Phase voltage sensing
    • KVAR / PF modes
    • RFI suppression
    • Min / Max exciter limiter
    • Exciter diode monitor
    • 1800 Frame generators (LV/MV)
    • Form wound
    • NEMA Class H insulation
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • (LV) Busbar connections, top / center mounted, top cable entry 60 Hz models: NEMA standard hole pattern
    • (MV) Busbar connections, right side extension box, bottom cable entry: - 60 Hz models: NEMA standard hole pattern
    • 3000 Frame generators (MV/HV)
    • Form wound
    • Permanent magnet
    • Anti condensation space heater
    • NEMA Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
    • Right side extension box, bottom cable entry
    Governing System
    • ADEM A4
    • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
    Lube System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
    • Prelube - required with prime and continuous; optional with standby
    Mounting System
    • Rails - Engine / Generator
    • Rubber anti-vibration mounts (shipped loose)
    • Dual 24-volt electric starting motors
    • Batteries and battery rack w/cables
    • Battery disconnect switch
    Service Instructions
    • Two PM Inspections
    General
    • Paint - Caterpillar yellow with high gloss black rails & radiator
    • RH Service (except oil filter service 60 Hz models: left hand service
    • Flywheel and flywheel housing-SAE No. 00
    • SAE standard rotation
    • *For HV EMCP4.3 control panel: Includes wall mount control panel, shipped loose, for customer mounting and 7.5 meter interconnect harness.
    • * For HV applications, customer to provide 120V secondary sensing, 5A secondary current sensing and harness between package and EMCP4.3 (drawing provided). CDVR is installed in wall mount.
    Air Inlet System
    • Air Cleaner; 4 x single element canister with service indicator(s).
    • Single stage air cleaner

    Optional Equipment

    Air Inlet System
    • Single stage air cleaner
    Control Panels
    • EMCP 4.4 (requires 1800 frame low voltage package)s
    • E-Stop - Only for use with 3000 frame generators and EMCP4.3
    • Load share module
    • EMCP mounting location - LV / MV (requires 1800 frame generator)
    • Customer AC-DC connection mounting location - LV / MV
    • Load share governor / auxiliary plate and auxiliary box (LV)
    • Remote speed adjust
    • Annunciator modules
    • Customer interface options
    • Generator temperature monitoring
    • Modbus monitoring of packages
    • Vandal proof panel door
    Cooling System
    • Package mounted radiator
    • Remote radiators
    • SCAC circuits
    • Fuel cooler
    Exhaust
    • Exhaust collectors / manifold
    Fuel System
    • Primary fuel filter
    General
    • Paint - colors (other than Caterpillar yellow) or high performance paints
    • US aid emblem
    Generator and Attachments
    • 480 Volts, Generators (LV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 - 1800 frame
    • 480 Volts, Generators (MV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 -- 1800, 3000 frame
    • Space heater kit
    • Thermostat for space heater
    • Differential current transformers (DCT): - 5, 9 and 15 kV class DCTs
    Instrumentation
    • Pyrometer and thermocouples
    • Harness - ECM interconnect
    Lube System
    • Lube oil heater
    • Oil pan drain valve
    • Standard sump oil pan
    • Lubricating oil
    • Electric prelube pump
    • Oil filters
    Crankcase Systems
    • Explosion relief valves
    Mounting System
    • Rubber anti-vibration mounts
    • Spring-type linear vibration isolators
    • IBC vibration isolators - shipped loose
    Power Connections
    • Center post busbars (LV) connections
    • Side / Rear monted busbars (LV)
    • Cable entry options (LV)
    • Control packaging (LV) - Enclosures
    • Power connection covers
    • Optional package mounted circuit breakers (LV)
    • 4000 Amp, 3 Pole, UL-100% rated circuit breakers
    • 4000 Amp, 3 Pole, IEC-Rated circuit breakers
    • 5000 Amp, 3 Pole, UL-100% rated circuit breakers
    • 5000 Amp, 3 Pole, IEC-rated circuit breakers
    • Circuit Breaker Harness
    • MV Power Connection Options: 1800 Frame generator side / rear mounted busbars - Left hand MV nema busbar - Right hand MV nema busbar
    • Cable entry options - 1800 frame (MV)
    • Neutral ground - (MV)
    • Masterpack breaker connections
    Service Tools - Barring Groups
    • Engine group
    • Group manual
    • Engine air powered
    • Control GP-airpowered group
    Special Tests / Reports
    • Generator test report
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard genset torsional vibration analysis (TVA) report
    • Custom genset TVA report
    • Fuel consumption test
    • Standard engine test charge
    Starting/Charging
    • 24 Volt power distribution box
    • 24 Volt electric starting motor
    • Air starting motor
    • Covers - starter locations
    • 24 Volt battery set - dry
    • Heavy duty battery set with rack
    • 35 and 50 Amp battery chargers
    • Jacket water heaters
    • Jacket water heater wiring groups
    • Jacket water heater wiring groups

    listofrelationships

    original

    Other Models in this Category

    Select Generator Type


    Hawthorne Power Systems Logo

    Request a Quote

    Why Cat is Better. Machine Comparison

    "
    With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
    Mark Cripe
    Helix Electric
    "

    San Diego - Power
    Kyle Farmer
    Engine Business Manager
    858.376.6821 office
    760.715.9565 mobile
    kfarmer@hawthornecat.com

    Ed Dawe
    EPG Sales Engineer
    858.376.6824 office
    808.342.1300 mobile
    edawe@hawthornecat.com

    Mark Reza
    Used Engine Sales Manager
    858.376.6840 office
    858.688.0076 mobile
    mreza@hawthornecat.com

    Phillip J. Smith (PJ)
    Field Service Manager
    858.376.6874 office
    858.688.0134 mobile
    psmith@hawthornecat.com

    Hawaii – Power
    Cliff Yuen
    Director of Sales & Rentals
    808.676.0322 office
    808.349.7767 mobile
    cyuen@hawthornecat.com

    Guam – Power
    Myver Hecita
    Power Systems Rental &
    Sales Representative
    671.649.4241 office
    671.898.2740 mobile
    mhecita@hawthornecat.com