New | ATC Service Entrance Rated MCCB & Power Breaker Based ATS

Cat® Service Entrance Rated (SER) automatic transfer switches (ATS) are designed to provide standby power emergency power to entire installation loads to protect against utility power interruption; yet allow the ATS to be as close as possible to the point of service entrance. By safely and in code compliance, integrating the necessary overcurrent protection and service disconnecting means into the automatic transfer switch, a single installation can be made at the service entrance. This design eliminates the need for a separate upstream fault protection and respective interconnections, which in turn reduces installation space, time, and cost. Breaker-based Service Entrance Rated transfer switches are available from 30A to 5000A.

Technical Summary
Rating Range30-5000A
Transfer TypeOpen / Closed / Delayed
Switch TypeMolded Case and Power Breaker
Ratings
MCCB30-1000A 2, 3, or 4 Pole
Fixed Mount Power Breaker200-3200A 2, 3, 4-Pole
Drawout Power Breaker200-5000A 2, 3, or 4-Pole
System Voltage Application120-600 Vac 50/60 Hz
Withstand(Power Breaker) Up to 100 kAIC at 600V 3 cycles
Applicable Testing
UL 1008 listed up to 3200A

4000A, and 5000A UL 891 listed

  • atc-100 On Residential & Light Commercial Mccb Based, Atc-300+ Or Atc-800 On Mccb & Power Breaker Ats Products
  • ul 1008 Service Entrance Listed (up To 3200a)
  • service Disconnect (both Off) Capability
  • integral Over Current Protection
  • lockout When In Disconnected Position (only)
  • service Entrance Labeled
  • integrated Design
  • disconnecting Neutral Assembly
  • ground Fault Protection Capability (all Ratings)
    (required By Code On Rating 480v, And 1000a Or Higher)
  • keyed Service Entrance Switch
  • draw-out Type Breakers (available On Power Breaker Ratings)
  • ul 891 For 4000-5000a
  • loads Protected Against Extended Power Loss
  • quick Restoration Of The Circuit After A Trip (versus A Fused Circuit That Requires Fuse Availability)
  • trip On A Fault Prohibits Transfer To The Emergency Source
  • fused Circuit Allows Switch Testing By Simulating An Actual Power Failure
  • lockable Disconnect Position Permits Safe Downstream Maintenance

listofrelationships

original

Other Models in this Category

Select Integrated System Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Kyle Farmer
Engine Business Manager
858.376.6821 office
760.715.9565 mobile
kfarmer@hawthornecat.com

Ed Dawe
EPG Sales Engineer
858.376.6824 office
808.342.1300 mobile
edawe@hawthornecat.com

Mark Reza
Used Engine Sales Manager
858.376.6840 office
858.688.0076 mobile
mreza@hawthornecat.com

Phillip J. Smith (PJ)
Field Service Manager
858.376.6874 office
858.688.0134 mobile
psmith@hawthornecat.com

Paul Karpf
Rental and Load Bank
General Manager
858.376.6888 office
858.688.0039 mobile
pkarpf@hawthornecat.com

Hawaii – Power
Cliff Yuen
Engine Business Manager
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com