New | C13 (50 Hz) China Non Road

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications
Minimum Rating350 kVA
Maximum Rating450 kVA
Emissions/Fuel StrategyLow Fuel, R96/EUIIIa
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Prime
Engine Specifications
Engine ModelC13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore5.12 in
Stroke6.18 in
Displacement762.8 in³
Compression Ratio16.3:1
AspirationAir to Air Aftercooled
Fuel SystemMEUI
Governor TypeAdem™A4
Generator Set Dimensions
Length - Maximum186.7 in
Width - Maximum79.3 in
Height - Maximum84 in

  • cat Generator Set Packages Have Been Fully Prototype Tested
  • accepts 100% Block Load In One Step And Meets Nfpa 110 Loading Requirements
  • conform To Iso 8528-5 Steady State And Transient Response Requirements

  • reliable, Rugged, Durable Design
  • field-Proven In Thousands Of Applications Worldwide
  • four-Stroke-Cycle Diesel Engine Combines Consistent Performance And Excellent Fuel Economy With Minimum Weight

  • superior Motor Starting Capability Minimizes Need For Oversizing Alternator
  • designed To Match Performance And Output Characteristics Of Cat Diesel Engines
  • robust Class H Insulation

  • user-Friendly Interface And Navigation
  • scalable System To Meet A Wide Range Of Installation Requirement
  • expansion Modules And Site-Specific Programming For Specific Customer Requirements

  • designed To Operate In Standard Ambient Temperatures Up To 55°c (131°f)
  • contact Your Cat Dealer For Specific Ambient And Altitude Capabilities

Cat Dealers Provide Extensive Post-Sale Support Including Maintenance And Repair Agreements. Cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries. The Caterpillar S•o•s℠ Program Cost Effectively Detects Internal Engine Component Condition, Even The Presence Of Unwanted Fluids And Combustion By-Products

  • components Used In The Generator Set Are Selected Based On Seamless Design Integration To Provide The Optimum Performance
  • the Generator Set Is Fully Assembled At A Caterpillar Facility Following Our Quality Guidelines
  • each Generator Set Package Is Tested Before Leaving The Caterpillar Facility
  • cat Product Support, Including Dealer Service, Parts And Warranty Covers The Entire Cat Power System

  • cat Dealers Have Over 1,800 Dealer Branch Stores Operating In 200 Countries
  • your Local Cat Dealer Provides Extensive Post-Sale Support, Including Maintenance And Repair Agreements

Standard Equipment

Air Inlet System
  • Air cleaner; light duty with disposable paper filter
  • Turbocharger
  • Aftercooler core
Control Panel
  • EMCP 4.2
Cooling System
  • Radiator and cooling fan with guard
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar Extended Life Coolant
Exhaust System
  • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
Fuel System
  • Primary fuel filter w/integral water separator & secondary filter
  • Flexible fuel lines
  • Fuel priming pump
  • Engine fuel transfer pump
  • Fuel coolersteel with single wall integral 8-hour fuel tank
Generator and Attachments
  • Integrated Voltage Regulator
  • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
  • A frame generator - IP21 Protection
  • Power center, IP22
  • Optional LC frame generator - IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel
Governing System
  • Cat Electronic Governor (ADEM A4)
Lube System
  • Lubricating oil
  • Oil drain valves
Packaged Generator Set
  • Service indicator
  • Disposable Air filter
  • Coolant level sight gauge
  • Low coolant level sensor
  • Coolant drain line with valve
  • Radiator package mounted
Mounting System
  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines.
Starting / Charging System
  • 24V battery with rack and cables
General
  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

European Certificates
  • Global certificate for CIS
  • EU certificate of conformance
Air Inlet System
  • Single element air cleaner
  • Dual element air cleaner
Circuit Breakers
  • Pad-lockable circuit breaker device
  • 3 Pole (IEC-100% rated) circuit breaker - Motorised
  • 3 Pole (IEC-100% rated) circuit breaker
  • 4 Pole (IEC-100% rated) circuit breaker
  • Circuit breaker (IEC) auxiliary contacts
  • Shunt trip for IEC circuit breaker
  • 4 Pole (IEC-100% rated) circuit breaker - Motorised
Control Panels
  • Local alarm modules: Local annunciator
  • Volt free contacts
  • EMCP 4.3, EMCP 4.4
  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
  • Remote annunciator modules
Cooling System
  • Radiator duct flange
  • Low coolant temperature alarm
  • Stone guards
Enclosures
  • High ambient sound attenuated enclosures
  • Sound attenuated enclosures
Exhaust System
  • 10, 25 and 35 dBA attenuation
  • Mufflers - End in / End out
  • 6 and 8 inch flange GP
  • Flexible 8 inch exhaust fittings
  • 6 and 8 inch elbow kit
Fuel System
  • Fuel transfer system controls
  • Integral dual wall fuel tank base
  • Manual fuel transfer pump
Generator and Attachments
  • Space heaters
  • LC frame generator
  • LC frame oversize generator
  • LC CIP generator
  • A frame oversize generator
  • A frame CIP generator
  • Permanent magnet generator
  • Ingress protection
Lube System
  • Manual sump pump
Mounting System
  • Narrow skid base
Starting / Charging System
  • 5 Amp single battery charger
  • Jacket water heater
  • Battery disconnect switch

listofrelationships

original

original

Other Models in this Category

Select Generator Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Kyle Farmer
Engine Business Manager
858.376.6821 office
760.715.9565 mobile
kfarmer@hawthornecat.com

Tim Roberts
Product Support
General Manager
858.376.6820 office
858.583.8460 mobile
troberts@hawthornecat.com

Mark Reza
Used Engine Sales Manager
858.376.6840 office
858.688.0076 mobile
mreza@hawthornecat.com

Phillip J. Smith (PJ)
Field Service Manager
858.376.6874 office
858.688.0134 mobile
psmith@hawthornecat.com

Hawaii – Power
Cliff Yuen
Director of Sales & Rentals
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com