New | XGC1900

In addition to improved fuel efficiency, the next generation XGC1900 rental generator provides significant power density advantages. Caterpillar developed new exhaust stacks that reduce spacing requirements for sites requiring multiple units.

Generator Set
Rating1900 ekW (2375 kVA) Continuous
Frequency50Hz
Voltage400 V
Engine
EngineCAT G3516H Gas Engine
FuelNatural Gas
Dimensions
Width - Without Chassis96 in
Height - Without Chassis114 in
Length - Without Chassis480 in
Weight - Without Chassis, With Lube Oil and Coolant77780 lb

Extensive Range Of Rental Ready Features To Meet Job Requirements And Applications.

Meets Most Worldwide Emissions Requirements Down To 500 Mg/Nm3 Nox Level Without After Treatment.

Compact, Four-Stroke-Cycle G3516h Gas Engine Provides Exceptional Dependability, Fuel Economy And Power Density For Reduced Total Cost Of Ownership High Altitude And Ambient Hardware Improvesengine’s Capability To Handle Electrical Loading Andunloading, As Well As Ambient And Altitude Capability. High Fuel Tolerant Hardware Improves Humiditytolerance And Allows Usage Of Lower Mn Fuel Operates On 24.10 To 93.95 Mj/Nm3(615 To 2386 Btu/Ft3) Dry Pipeline Natural Gas Island Mode Feature Improves Engine's Capability To Handle Electrical Loading And Unloading

Emcp 4.3 Control Panel Offers Engine And Generator Monitoring And Protection Fully Featured Power Metering, Protective Relaying, And Engine/Generator Control And Monitoring On-Package Auto Paralleling Controls Agc-4 Provides Paralleling, Load Sharing, Vfd Control, And Additional Generator Protection

Cat Sr5 Generator Designed To Match The Performance And Output Characteristics Of The Cat Gas Engine. Class H Insulation Operating At Class F Temperature Rise For Extended Life. System 4 Insulation Protection And Anti-Condensation Space Heaters. Integrated Automatic Voltage Regulation (cat Ivr) Provides Enhanced System Monitoring.

Provides 40⁰c (104⁰f) Ambient Capability With 500 Mg/Nm3 Nox (1g/Hp-Hr) At 100% Continuous Rating Before Derate @ 500m. Variable Frequency Drive Fan Controls Improve Partial Load Fuel Consumption. Energy Efficient Electric Drive Fan.

Meets 79 Db(a) At 7 Meters Or Below Per Sae J1074. 40' Iso High Cube Container, 9-High Stack Csc Certified. Service And Personnel Doors. External Emergency Stop Buttons On Each Side Ofunit. Externally-Accessible Controls.

Remote Monitoring For Fleet Management And Asset Tracking.

110% Spill Containment Of Onboard Engine Fluids. Positive Crankcase Fumes Ventilation.

Generator Set Manufactured In Iso 9001:2000 Compliant Facility. Package Factory Designed And Production Tested.

Cat® Dealers Provide Extensive Post Sale Support Including Maintenance And Repair Agreements. Supported 100% By The Cat Dealer With Warranty On Parts And Labor.

Standard Equipment

Engine
  • G3516H, V16, 4-stroke-cycle, gas engine. Operates on 24.10 to 93.95 MJ/Nm3 (615 to 2386 btu/ft3) dry pipeline natural gas. Turbocharged Separate Circuit Aftercooled.
Generator
  • Double bearing SR5 1866 frame, brushless, form wound, 12-lead design, permanent magnet excited, three-phase, with Cat IVR, Class H insulation operating at Class F temperature. Stator and Bearing temperature monitoring and anti-condensation space heaters.
Containerized Module
  • 40' ISO high cube container, 9-high stack CSC certified. Sound attenuated 79 dB(A) @ 7 m (23 ft) Sound attenuated air intake louvers and 2lockable personnel doors with panic release LH and RH engine service doors integrated intocontainer side walls 3” ANSI flange customer fuel connection
Cooling
  • Standard cooling provides 40⁰C (104⁰F) ambient capability with 500mg/Nm3 NOx at 100% Continuous rating before derate, @ 500m
Generator Controls And Protection
  • On Package EMCP 4.3 Control Panel System Offers engine and generator monitoringand protection, voltage regulation with Cat IVRimproves transient response performance. Controls provide auto paralleling AGC-4 controller, load sharing, VFDcontrol, and primary generator protection for greaterversatility, package utilization and monitoring.
Modes of Operation
  • Provides for single unit stand-alone operation,island mode paralleling and load sharing withother power modules, and single unit-to-utilitymode paralleling for base load control
Lube Oil Make-Up System
  • Oil pan-mounted oil level regulator and 114 L (30 gal) oil tank Low level annunciation

listofrelationships

original

original

original

original

Other Models in this Category

Select Generator Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Kyle Farmer
Engine Business Manager
858.376.6821 office
760.715.9565 mobile
kfarmer@hawthornecat.com

Tim Roberts
Product Support
General Manager
858.376.6820 office
858.583.8460 mobile
troberts@hawthornecat.com

Mark Reza
Used Engine Sales Manager
858.376.6840 office
858.688.0076 mobile
mreza@hawthornecat.com

Jeff Reid
Service Manager
858.376.6890 office
858.472.1852 mobile
jreid@hawthornecat.com

Hawaii – Power
Cliff Yuen
Director of Sales & Rentals
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com