New | M 32 E Marine Generator Set

The M 32 E is designed for the offshore market focused on generator set application. The 720/750 rpm concept will reduce generator costs. Charge air cooler housing and charge air cooler allow easier disassembly and cleaning. The new design still supports operation at any ambient condition without load reduction. We offer a generator set application for customers operating the engines mainly below 47 %.

Generator Set Specifications
Minimum Rating3165 kWe (3960 kVA)
Maximum Rating5747 kWe (5940 kVA)
Emissions/Fuel StrategyIMO II
Engine Specifications
Bore12.6 in
Stroke18.1 in
Swept Volume2257.88 in³
Configuration6,8,9 Cylinder
Generator Set Dimensions
Weight73.0 - 98.0 t (160937 - 216053 lbs)
Length9566 - 11156 mm (376.6 - 439.2 in)
Width2600 mm (102.4 in)
Height4565 - 4770 mm (179.7 - 187.8 in)

The Robust Design And Moderate Speed Permits Unlimited, Continuous Operation With Heavy Fuel Oil. Engine And Electrics Are Tested Prior To Delivery.

Nodular cast-iron engine block with integrated ducts for lubricating oil and charge air

Emission reduction technology

Installation friendly, due to pumps and filters installed on the engine

Standard Equipment

Air Inlet System
  • Air intake silencer / filter
Control System
  • Load sharing unit (for multiple engine plant only)
  • Modular Alarm Control and Protection System (MACS)
  • Speed governor
Cooling System
  • Electric cooling water preheater
  • HT cooling water pump (engine driven)
  • HT cooling water pump (engine driven)
Exhaust System
  • Exhaust gas expansion joint
  • Exhaust gas insulated manifolds
  • Turbocharger at counter-flywheel end
Fuel System
  • Fuel circulating pump (attached / for MDO/MGO only)
  • Fuel indicator filter
  • Fuel pressure valve (fitted / for MDO/MGO only)
Instrumentation
  • Control push buttons and lamps
  • Local control panel
  • Pressure and temperature indicator
Lube System
  • Engine with dry sump
  • Lube oil cooler (separate)
  • Lube oil pump (engine driven)
  • Lube oil self-cleaning filter
  • Oil sump in base frame
  • Pre-lubricating oil pump (electric driven / fitted on base frame)
  • Pressure regulating valve
Mounting System
  • Flexible pipe connections
  • High flexible coupling
  • Resilient mounting on base frame
Starting System
  • Electrical barring device
  • Starting air valve
General
  • Engine, flexible coupling and generator mounted on a common base frame
  • Flywheel cover
  • Lifting device (rental)
  • Torsional Vibration Calculation (TVC)

Optional Equipment

Air Inlet System
  • Air inlet shut-off valve
  • Air intake transition piece
  • Expansion joint
  • Silencer / filter
Control System
  • Air injection control (for better load acceptance)
  • Electronic speed governor
  • Remote indicators (start air pressure, engine speed, etc.)
  • Starter for electric driven pumps
  • 24 DC UPS
Cooling System
  • CW piping for generator cooling on base frame
  • CW piping for lubricating oil cooler on base frame
  • FW/SW plate cooler
  • HT cooling water pump (electric driven)
  • LT cooling water pump (electric driven)
  • Sea water cooling pump (electric driven)
  • Temperature control valve
Exhaust System
  • Silencer (with or without spark arrester)
Fuel System
  • Fuel oil cooler
  • HFO final preheater
  • HFO pressure regulating valve
  • HFO self-cleaning automatic filter
  • HFO supply and booster pumps (electrical driven)
  • HFO treatment and supply modules
  • HFO viscosity control device
  • Mixing tank
Lube System
  • Lube oil centrifuge
  • Lube oil cooler fitted on base frame
  • Lube oil pump (electrical driven)
  • Lube oil treatment and combined modules
  • Temperature control valve
Mounting System
  • Double resilient mounting (engine and base frame)
  • Engine resiliently mounted on base frame, base frame rigidly mounted
Starting System
  • Starting air compressor
  • Starting air receiver
General
  • Engine PTO coupling
  • Generator customer supply
  • Part load optimization kit for constant speed engine (SFOC improvement, smoke reduction)
  • Part load optimization kit for variable speed engine (massive SFOC improvement,…)
  • PTO shaft on counter-flywheel side

listofrelationships

original

Other Models in this Category

Select Marine Power System Type


Hawthorne Power Systems Logo

Request a Quote

Why Cat is Better. Machine Comparison

"
With only a few days notice, we were able to get the emergency system working properly. Hawthorne Cat provided great leadership and excellent field support.
Mark Cripe
Helix Electric
"

San Diego - Power
Kyle Farmer
Engine Business Manager
858.376.6821 office
760.715.9565 mobile
kfarmer@hawthornecat.com

Tim Roberts
Product Support
General Manager
858.376.6820 office
858.583.8460 mobile
troberts@hawthornecat.com

Mark Reza
Used Engine Sales Manager
858.376.6840 office
858.688.0076 mobile
mreza@hawthornecat.com

Jeff Reid
Service Manager
858.376.6890 office
858.472.1852 mobile
jreid@hawthornecat.com

Hawaii – Power
Cliff Yuen
Director of Sales & Rentals
808.676.0322 office
808.349.7767 mobile
cyuen@hawthornecat.com

Guam – Power
Myver Hecita
Power Systems Rental &
Sales Representative
671.649.4241 office
671.898.2740 mobile
mhecita@hawthornecat.com