Power System

Cat® CG – ATS for general purpose applications

Cat® CG Series

The CG Series – Contactor-type, Open Transition (CG) and Delayed Transition (CGD) ATS for general purpose applications offers functionality for critical emergency power applications in commercial and light industrial applications, with an enhanced feature set and LCD HMI interface.

The CG provides a durable mechanism that is tested up to 6,000 cycles. Electrical system parameters are set via the HMI and pre-configuration file upload is available via USB or Bluetooth connection.

The CG Series – Contactor-type, Open Transition (CG) and Delayed Transition (CGD) ATS for general purpose applications offers functionality for critical emergency power applications in commercial and light industrial applications, with an enhanced feature set and LCD HMI interface.

The CG provides a durable mechanism that is tested up to 6,000 cycles. Electrical system parameters are set via the HMI and pre-configuration file upload is available via USB or Bluetooth connection.

Equipment Highlights

Product Features
        
  • Voltage and frequency sensing of both sources and load
  •     
  • USB port to upload/download settings
  •     
  • Available Bluetooth connection and enhanced communication capabilities
  •     
  • Password protection LCD HMI
  •     
  • Integrated help button and menu
  •     
  • Automatic Configuration Function
Control Panel
        
  • TruOne L3 – CG LCD HMI to set electrical system parameters with file upload via USB or Bluetooth connection.
Functions
        
  • Provision of transfer & re-transfer control signals
  •     
  • Provision of engine/generator start and shutdown signals
  •     
  • Permit user programming of set points
  •     
  • Display real time and historical information
  •     
  • Permit system testing
  •     
  • Store all parameters in nonvolatile memory
Standards
        
  • UL 1008, NFPA 70, 99, 101 and 110
  •     
  • NEMA ICS 10
  •     
  • cUL

Specs + Downloads

Specs
  • Rating Range: 30 - 3000 A
  • Transfer Type: Open Transition (CG), Delayed Transition (CGD)
  • Switch Type: Contactor
  • Product nodes: 30, 60, 100, 125, 160, 200, 260, 400, 600, 800, 1000, 1200, 1600, 2000, 2600, 3000A
  • Rated Voltage and Frequency: 200-480VAC, 50/60 Hz
  • Phase system: Single and Three (three phase only >600A)
  • Number of poles: 2, 3 and 4 (3 & 4 pole only >600A)
  • Neutral configuration: Optional Solid or Switched neutral
  • Product type: Open transition (I-II), Delayed Transition (I-O-II)

Photo Gallery

Let us help you find what you are looking for.