3512B (60 Hz) 1500 kW with Upgradeable Package

3512B Diesel Generator Set

3512B (60 HZ) 1230-1500 kW Diesel Generator with upgradeable package models offer a great degree of customization for mission critical, continuous, standby and prime applications.

3512B  Diesel Generator Sets

DESCRIPTION

1230 - 1500 kW at 60Hz Diesel Genset
Our industrial diesel generators produce reliable power from 1230 to 1500 kW at 60 Hz. The 3512B diesel gensets are made to provide continuous power solutions for your business operation as well as supply standby and emergency power. Diesel engines are parallelable and meet prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Cat® generators are available in low fuel consumption and low emissions configurations.
FAQS
Q. Can we burn HVO (hydrotreated vegetable oil) in this generator to help achieve our Sustainability goals?
A. Yes, the 3512B can burn HVO to help reduce emissions.
Q. Does the Cat generator meet 10 second starting requirements?
A.Yes, with the appropriate configuration our generators are capable of 10 second starting to meet emergency needs or customer requirements.
Q.Does this generator comply with ISO 8528 guidelines?
A.Yes, the 3512B, like all of our generators, is tested in accordance with the load steps outlined in with ISO 8528, Part 5.
Q.Is this generator noisy?
A.We offer a number of options for sound attenuation including silencers and sound attenuated enclosures for many of our generators to reduce the dB(A) levels.
Q.Where can I obtain replacement parts for a Cat generator?
A.Replacement spares are available from Cat dealers in over 200 countries worldwide.1230 - 1500 kW at 60Hz Diesel Genset
Our industrial diesel generators produce reliable power from 1230 to 1500 kW at 60 Hz. The 3512B diesel gensets are made to provide continuous power solutions for your business operation as well as supply standby and emergency power. Diesel engines are parallelable and meet prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100%rated load in one step. Generator sets offer efficiently lower fuel consumption and emissions.
Q. Can we burn HVO (hydrotreated vegetable oil) in this generator to help achieve our Sustainability goals?
A. Yes, the 3512B can burn HVO to help reduce emissions.Electric Power

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

One Safe Source

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

  • Standard Equipment
  • Optional Equipment
  • Specs
  • Docs

Standard Equipment

  • Air Inlet System
    • Air cleaner; single element canister type with service indicator
  • Control System
    • True RMS AC metering, 3-phase, +/-2% accuracy
  • Control Panel
    • DC volts
    • 24 Volt DC operation
    • kVA (per phase, average & percent)
    • Engine cool-down timer
    • Coolant temperature
    • kW-hr (total)
    • Amps (per phase & average)
    • Over/under frequency (81 o/u)
    • Text alarm/event descriptions
    • Accessory module data link
    • Alarm acknowledge
    • Warning/shutdown with common LED indication of shutdowns for:
    • Auto/start/stop control
    • Controls:
    • Failure to start (overcrank)
    • Generator mounted - rear facing
    • kVAr (per phase, average & percent)
    • kVAr-hr (total)
    • Reverse reactive power (kVAr) (32RV)
    • Volts (L-L & L-N)
    • Serial annunciator module data link
    • 4 programmable relay outputs (Form A)
    • Lamp test
    • Operating hours
    • Overcurrent (50/51)
    • kW (per phase, average & percent)
    • Communications:
    • 6 programmable digital inputs
    • RPM
    • Engine cycle crank
    • 2 Programmable relay outputs (Form C)
    • IVR includes reactive droop capability, 3-phase voltage sensing
    • High coolant temperature
    • Digital indication for:
    • Environmental sealed front face
    • Power factor (per phase & average)
    • Speed adjust
    • Emergency stop pushbutton
    • Limiter and exciter diode monitor
    • Low oil pressure
    • EMCP 4.2B
    • Low coolant level
    • 2 Programmable digital outputs
    • KVAR/PF modes, RFI suppression, min/max exciter
    • Oil pressure (psi, kPa or bar)
    • Customer data link (Modbus RTU)
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Overspeed
    • Frequency (Hz)
    • Emergency stop
    • Generator set packages include Caterpillar's voltage regulator (IVR)
    • Reverse power (kW) (32)
    • Low coolant temperature
    • Generator phase sequence
    • Programmable protective relaying functions:
    • Over/under voltage (27/59)
  • Cooling System
    • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
    • Fan and belt guards
    • JWAC
    • Coolant drain line with valve
    • Coolant level sensors (Not included with packages without radiator)
  • Exhaust
    • Dry exhaust manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Fuel cooler; not included with packages without radiator
    • Fuel priming pump
    • Secondary fuel filters
    • Flexible fuel lines - shipped loose
  • Generators and Attachments
    • NEMA Class H insulation
    • Winding temperature detectors
    • Internal excitation (IE) or Permanent magnet excitation (PMG)
    • LV
    • 6 Lead
    • 60 Hz models: NEMA standard hole pattern
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • 3 Phase brushless, Salient pole
    • Busbar connections, top center mounted, top cable entry
    • Random wound
  • Governing System
    • Woodward 2301A isochronous governor
  • Lube System
    • Oil drain lines and valve
    • Lubricating oil
    • Integral lube Oil cooler
    • Fumes disposal
    • Gear type lube oil pump
    • Oil filter, filler and dipstick
  • Mounting System
    • Rails - engine/generator/radiator mounting
    • Rubber anti-vibration mounts - shipped loose
  • Starting / Charging System
    • Battery disconnect switch
    • Battery and battery rack w/cables
    • 24-Volt electric starting motor
    • 50 Amp Charging alternator
  • General
    • SAE standard rotation
    • Paint - Caterpillar yellow with high gloss black rails & radiator
    • Flywheel and Flywheel housing-SAE No. 00
    • RH service

Optional Equipment

  • Air Inlet System
    • Air cleaner: Includes installed single element Cat filter and service indicator
    • Dual element air filters
    • Single stage air cleaners
  • Control Panels
    • Cat connect (must choose one)
    • RTD module - may select one
    • Modbus monitoring of packages
    • First local annunicator
    • EMCP 4.3, EMCP 4.4
    • CAN2 network equipment
    • Remote custom annunciator
    • Locale discrete I / O package
    • Vandle proof panel door
  • Cooling System
    • Optional radiator arrangements
    • Water level gauge
    • Coolant
  • Control System
    • Generator temperature monitoring
  • Exhaust System
    • Exhaust Y Adapters
    • Exhaust elbows
    • Mufflers
    • Flexible fittings
    • Exhaust flange and expanders
  • Generators and Attachments
    • Space heater control
    • Generator conversion
    • Space heater
  • Instrumentation
    • Pyrometer and thermocouples
  • Lube System
    • Oil level regulator
    • Prelube manual sump pump
    • Electric prelube sump pump
    • Lube oil
  • Special Tests / Reports
    • PGS Test report @ 0.8 power factor
    • Generator test report
    • Standard generator TVA report
    • PGS Test report @ 0.8 power factor
    • Custom generator TVA report
    • Torsional vibration analysis
    • PGS Test report @ 1.0 power factor
    • Standard engine test charge
    • Generator test report
    • Standard engine test charge
    • PGS Test report @ 1.0 power factor
    • Generator fuel consumption test
  • General
    • Barring devices
  • Crankcase System
    • Ventilation system
    • Protection systems
  • Batteries and Battery Housing
    • 24 Volt battery set - Dry
    • Battery chargers - 10, 20 and 35 amp
  • Power Connection System
    • EMCP voltage and current sensing groups
    • Breaker power connections
    • Center post busbars
  • Circuit breaker - LV Packages
    • Right hand power connections
    • Electronically operated circuit breakers
  • Mounting System
    • Low efficiency isolators
    • Spring type vibration isolators
    • Spring type vibration isolators
    • Low efficiency isolators puck
  • Power Connections
    • Low voltage - Package mounted circuit breakers
    • Low voltage - 1400 and 1600 Frame generators
    • Electrically operated circuit breakers
    • Low voltage - Power connection options
  • Starting / Charging System
    • Jacket water heater wiring groups
    • 35 Amp Battery charger
    • 20 Amp Battery charger
    • Jacket water heaters
    • 10 Amp Battery charger
    • Electric starting motors
    • Starter cover
    • Batteries, racks and cables
  • Starting / Charging Systems
    • Electric starting motors
    • Starter cover
    • Jacket water heater
  • Extended Service Coverage
    • Gold - 36,48, 60, 120 month coverage
    • Cat branded commercial power system
    • Silver - 36 ,48, 60, 120 month coverage
    • Platinum - 24, 36, 48, 60, 120 month coverage

Specs

Overview

Long Name:
3512B Diesel Generator Set
Name:
3512B (60 Hz) 1500 kW with Upgradeable Package
Brand:
Cat
Status:
Current

Generator Set Specifications

Standby Rating
1500/1400 kW
Prime Power Rating
1360/1275 kW
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Maximum Rating
1500 kW
Minimum Rating
1230 kW

Engine Specifications

Engine Model
3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
6.69 in / 170 mm
Stroke
7.48 in / 190 mm
Displacement
51.8 in³ / 3161.03 l
Compression Ratio
14.0:1 Std 15.5:1 HD
Aspiration
TA
Fuel System
Electronic Unit Injection
Governor Type
ADEM™ A3

Generator Set Dimensions

Length - Maximum
207.8 in / 5279 mm
Width - Maximum
90 in / 2286 mm
Height - Maximum
94.9 in / 2409 mm
Dry Weight - Genset (minimum)
24297 lb / 11021 kg
Dry Weight - Genset (maximum)
24959 lb / 11321 kg

SEE HOW 3512B (60 Hz) 1500 kW with Upgradeable Package COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Diesel Generator Sets
3512B (60 Hz) 1500 kW with Upgradeable Package
3512B  Diesel Generator Sets
Brand
Cat
Status
Current
Standby Rating
1500/1400 kW
Prime Power Rating
1360/1275 kW
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Maximum Rating
1500 kW
Minimum Rating
1230 kW
Engine Model
3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
6.69 in / 170 mm
Stroke
7.48 in / 190 mm
Displacement
51.8 in³ / 3161.03 l
Compression Ratio
14.0:1 Std 15.5:1 HD
Aspiration
TA
Fuel System
Electronic Unit Injection
Governor Type
ADEM™ A3
Length - Maximum
207.8 in / 5279 mm
Width - Maximum
90 in / 2286 mm
Height - Maximum
94.9 in / 2409 mm
Dry Weight - Genset (maximum)
24959 lb / 11321 kg
Diesel Generator Sets
3512B (60 Hz)
3512B  Diesel Generator Sets (Rear Right)
Brand
Cat
Status
Current
Standby Rating
1500/1400 ekW
Prime Power Rating
1360/1275 ekW
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Maximum Rating
1500 ekW
Minimum Rating
1230 ekW
Engine Model
3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
6.69 in / 170 mm
Stroke
7.48 in / 190 mm
Displacement
3573.55 in³ / 58.56 l
Compression Ratio
14.0:1 Std 15.5:1 HD
Aspiration
TA
Fuel System
Electronic Unit Injection
Governor Type
ADEM™ A3
Length - Maximum
221.9 in / 5637.5 mm
Width - Maximum
90 in / 2286 mm
Height - Maximum
93.2 in / 2367.2 mm
Dry Weight - Genset (maximum)
25090 lb / 11380 kg
Diesel Generator Sets
3512C (1750 ekW, 60 Hz)
3512C_50Hz_Flush_Mount,  Rear Right
Brand
Cat
Status
Current
Standby Rating
1750 ekW
Prime Power Rating
1600 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 2
Voltage
380 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical
Maximum Rating
1750 ekW
Minimum Rating
1600 ekW
Engine Model
3512C ATAAC, V-12, 4-Stroke Water-Cooled Diesel
Bore
6.69 in / 170 mm
Stroke
8.46 in / 215 mm
Displacement
3574 in³ / 58.6 l
Compression Ratio
14.7:1
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
ADEM™ A3
Length - Maximum
262.9 in / 6676.8 mm
Width - Maximum
89.8 in / 2281.2 mm
Height - Maximum
110 in / 2794 mm
Dry Weight - Genset (maximum)
32660 lb / 14820 kg