ATC Power Breaker & Case Switch Automatic Transfer Switch
ATC Power Breaker & Case Switch Automatic Transfer Switch
DESCRIPTION
Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open transition power case switch-based Automatic Transfer Switch (ATS) will provide fully functioning transfer in applications where a momentary loss of power is acceptable on retransfer from emergency to normal power supply. The Cat power case switch-based ATS also permits periodic testing of the emergency source without interrupting power to the loads and are available from 200 to 5000.Product Features
- ATC-800 microprocessor-based controller
- Voltage and frequency sensing
- Fastest switching times available (<3 cycles)
- Full 60-cycle short time withstand capability
- Multiple field programmable time delays
- Switch position indication
- Source availability indication
- Safe manual transfer under load
- Source 1 and 2 auxiliary contacts
- Programmable plant exerciser
- System test pushbutton
- Load shed from emergency
- Mimic diagram
- True RMS three phase voltage sensing on Source 1, Source 2 and Load
- Frequency sensing on Source 1 and Source 2
- Mechanical (cable) and electrical interlocking to prevent paralleling of sources
- Safe manual operation under full load with permanently affixed operating handle
- Ambient temperature range: -40°C to 40°C (-40°F to 104°F)
- Operating temperature range: -20°C to 70°C (-4°F to 158°F)
- Operating humidity: up to 90%
- Relative humidity (non-condensing)
- Source paralleling duration is limited to 100 msec or less
- Source availability indication
- Standard Equipment
- Optional Equipment
- Specs
- Docs
Standard Equipment
- Controls and Wiring
- All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
- Enclosure
- Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.
Optional Equipment
- Available Options
- Load sequencing contacts
- Multi-meter options available
- Controller availability: ATC-100, ATC-300+,and ATC-800
- 2- or 4-position test switch
- Remote communications
- Integral overcurrent protection
- Field selectable, multi ratio, control voltage transformer 50/60 Hz
- Suitable for service entrance
- Space heaters
- Open or closed transition
- Surge suppression
- Selectable automatic or non-automatic operation
- Optional Delayed Transition includes:
- Time delay neutral
- In-phase transition
- Pre-transfer signal with 1 N.O. and 1 N.C. contacts
Specs
Overview
Long Name:
ATC Power Breaker & Case Switch Automatic Transfer Switch
Name:
ATC Power Breaker & Case Switch Automatic Transfer Switch
Brand:
Caterpillar
Status:
Current
Technical Summary
Rating Range
200 to 5000A
Transfer Type
Open Transition
Switch Type
Power Breaker
Ratings
Control Power
Fixed Mount 200-3200A 2, 3, or 4 Pole
Drawout 200-5000A 2-, 3-, 4-pole
Drawout 200-5000A 2-, 3-, 4-pole
System Voltage Application
120 - 600 Vac, 50/60 Hz
Time Withstand
85,000 for 30 cycles
Withstand
100,000 amps withstand/closing/ interrupting at 600 Vac
Applicable Testing
CSA C22.2 No. 178 certified
IBC 2006, CBC 2007 and OSHPD
SEE HOW ATC Power Breaker & Case Switch Automatic Transfer Switch COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.
ATS ATC Breaker / Contactor
ATC Power Breaker & Case Switch Automatic Transfer Switch
- Brand
- Caterpillar
- Status
- Current
- Rating Range
- 200 to 5000A
- Transfer Type
- Open Transition
- Switch Type
- Power Breaker
- Control Power
- Fixed Mount 200-3200A 2, 3, or 4 Pole<br>Drawout 200-5000A 2-, 3-, 4-pole
- System Voltage Application
- 120 - 600 Vac, 50/60 Hz
- Withstand
- 100,000 amps withstand/closing/ interrupting at 600 Vac
- Applicable Testing
- <br>CSA C22.2 No. 178 certified</br><br>IBC 2006, CBC 2007 and OSHPD</br>
Selected Model
ATS ATC Breaker / Contactor
ATC Molded Case Circuit Breaker & Molded Case Switch ATS
- Brand
- Caterpillar
- Status
- Current
- Rating Range
- 30-1000A
- Transfer Type
- Open transition
- Switch Type
- Molded Case
- Control Power
- 30-1000A 2, 3, or 4 Pole, 100% Rated
- System Voltage Application
- 120 - 600 Vac, 50/60 Hz
- Withstand
- 100,000 amps withstand/closing/ interrupting at480 Vac
- Applicable Testing
- CSA C22.2 No. 178 certified, IBC 2006, CBC 2007 and OSHPD
ATS ATC Breaker / Contactor
ATC Power Breaker Bypass Isolation Open/Closed Transition ATS
- Brand
- Caterpillar
- Status
- Current
- Rating Range
- 200-5000A
- Transfer Type
- Bypass isolation, Closed transition
- Switch Type
- Power Breaker
- Control Power
- 200-5000A, 2-, 3-, 4-pole<br>100% rated Short
- System Voltage Application
- 120-600 Vac 50/60 Hz
- Withstand
- 100 kAIC at 600V, 3 cycles
- Applicable Testing
- CSA C22.2 No. 178 certified<br> UL 1008 listed up to 3200A<br>4000A, and 5000A UL 891 listed