2806FA-E18TAG1 and TAG2
2806FA-E13TAG1 and TAG2 Electric Power Diesel Engine
DESCRIPTION
The 2806FA owes its lineage to a long line of proven industrial and electric power engines that have performed for millions of hours all over the world. The 2806FA has been developed exclusively for India's latest emission standards. The SCR-only aftertreatment helps deliver cleaner emissions and excellent performance for years to come.Compact, clean and efficient power
Exceptional power to weight ratio and compact size give optimum power density for ease of installation and more cost effective transportation
Designed to provide excellent service access for ease of maintenanceEconomic power
Mechanically operated unit fuel injectors with electronic control combined with carefully matched turbocharging give excellent fuel atomsation and combustion with optimum economy
Reliable power
Developed and tested using the latest engineering techniques and finite element analysis for high reliability, low oil usage and low wear rates
High compression ratios ensure clean rapid starting in all conditions Perkins global product support is designed to enhance the customer experience of owning a Perkins powered machine. We deliver this through the quality of our distribution network, extensive global coverage and a range of Perkins supported OEM partnership options. So whether you are an end-user or an equipment manufacturer our engine expertise is essential to your successProduct support
Perkins actively pursues product support excellence by ensuring our distribution network invest in their territory � strengthening relationships and providing more value to you, our customer
Through an experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their fingertips covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts and service. We give 100% reassurance that you receive the very best in terms of quality for lowest possible cost .. wherever your Perkins powered machine is operating in the world- Standard Equipment
- Specs
- Docs
Standard Equipment
- Air inlet system
- Mounted air filter
- Cooling system
- Gear-driven circulating pump
- Mounted belt-driven pusher fan
- System designed for ambients up to 55�C (131�F)
- Electrical equipment
- 3 level engine protection system
- 24 volt starter motor and 24 volt 85 amp alternator with DC output
- ECM mounted on engine with wiring looms and sensors
- Flywheels and flywheel housing
- High inertia flywheel to SAE J620 size 14
- SAE No. 1 flywheel housing
- Fuel system
- Governing to ISO 8528-5 class G3 with isochronous capability
- Mechanically actuated electronically controlled unit fuel injectors with full authority electronic control
- Replaceable spin on fuel filter elements with primary filter/water separator
- Mountings
- Front engine mounting bracket
- Oil system
- Full-flow replaceable filter
- Oil cooler and filter
- Wet sump with filler and dipstick
- Optional equipment
- CAM and crank speed sensors
- Temperature and pressure sensors for gauges
- Starter provided. Facility for second starter
Specs
Overview
Long Name:
2806FA-E13TAG1 and TAG2 Electric Power Diesel Engine
Name:
2806FA-E18TAG1 and TAG2
Brand:
Perkins
Status:
Current
Total Power Range
Gross Mechanical Output
611
Typical Electrical Output
N/A
Rated Speed
1500 rpm
50 Hz Typical Electrical Output
Prime
N/A
Standby
N/A
Baseload
N/A
60 Hz Typical Electrical Output
Prime
N/A
Standby
N/A
Emission Standards
Emissions
India CPCB IV+
General
Number of Cylinders
6 vertical inline
Bore
5.7 in / 145 mm
Stroke
7.2 in / 183 mm
Displacement
1105 in³ / 18.1 l
Compression Ratio
16.0:1
Aspiration
Turbocharged aftercooled
Combustion System
Diesel Compression Ignition
Rotation from Flywheel End
Anti-clockwise
Cooling System
N/A
Aftertreatment
DOC+SCR+AMOX
Typical Alternator Efficiency
95%
Switchable
No
Engine Dimensions*
Length
71 in / 1805 mm
Width
39 in / 993 mm
Height
56.3 in / 1430 mm
Dry Weight
3294 lb / 1494 kg
Aftertreatment Dimensions*
Length
39.5 in / 1004 mm
Width
20.8 in / 528 mm
Height
38.4 in / 975 mm
Weight
245 lb / 111 kg
Disclaimer
Note 1
*Final dimensions dependent on selected options
Definitions
Prime Power
Variable load. Unlimited hours usage with an average load of 70% of the published prime power rating. A 10% overload is available for 1 hour in every 12 hour of operation.
Standby Power
Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted.
Baseload
N/A
60 Hz Typical Electrical Output
Baseload
N/A
General
Aftertreatment
Remote mounted
Cycle
N/A
SEE HOW 2806FA-E18TAG1 and TAG2 COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.
Diesel Engines
2806FA-E18TAG1 and TAG2
- Brand
- Perkins
- Status
- Current
- Gross Mechanical Output
- 611
- Typical Electrical Output
- N/A
- Rated Speed
- 1500 rpm
- Prime
- N/A
- Standby
- N/A
- Emissions
- India CPCB IV+
- Number of Cylinders
- 6 vertical inline
- Bore
- 5.7 in / 145 mm
- Stroke
- 7.2 in / 183 mm
- Displacement
- 1105 in³ / 18.1 l
- Compression Ratio
- 16.0:1
- Aspiration
- Turbocharged aftercooled
- Combustion System
- Diesel Compression Ignition
- Rotation from Flywheel End
- Anti-clockwise
- Cooling System
- N/A
- Aftertreatment
- Remote mounted
- Typical Alternator Efficiency
- 95%
- Switchable
- No
- Length
- 39.5 in / 1004 mm
- Width
- 20.8 in / 528 mm
- Height
- 38.4 in / 975 mm
- Dry Weight
- 3294 lb / 1494 kg
- Note 1
- *Final dimensions dependent on selected options
- Prime Power
- Variable load. Unlimited hours usage with an average load of 70% of the published prime power rating. A 10% overload is available for 1 hour in every 12 hour of operation.
- Standby Power
- Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted.
Selected Model
Diesel Engines
904J-E36TAG
- Brand
- Perkins
- Status
- Current
- Gross Mechanical Output
- 50-61 kW
- Typical Electrical Output
- 54-66 kVA (43-53kWe)
- Rated Speed
- 1500/1800 rpm
- Prime
- 43 kWe
- Standby
- 47 kWe
- Emissions
- EU Stage V
- Number of Cylinders
- 4 vertical inline
- Bore
- 3.9 in / 98 mm
- Stroke
- 4.7 in / 120 mm
- Displacement
- 219.7 in³ / 3.6 l
- Compression Ratio
- 17:1
- Aspiration
- Turbocharged aftercooled
- Combustion System
- Direct injection
- Rotation from Flywheel End
- Anti-clockwise
- Cooling System
- Liquid
- Aftertreatment
- -
- Typical Alternator Efficiency
- 89.5-92%
- Switchable
- Yes
- Length
- 41.6 in / 1056 mm
- Width
- 27.3 in / 693 mm
- Height
- 42.6 in / 1083 mm
- Dry Weight
- 1127 lb / 511 kg
- Note 1
- *Final dimensions dependent on selected options
- Prime Power
- Power available at variable load in lieu of a main power network. Overload of 10% is permitted for one hour in every 12 hours of operation.
- Standby Power
- Power available at variable load in the event of a main power network failure. No overload is permitted.
Diesel Engines
2806J-E18TAG1
- Brand
- Perkins
- Status
- Current
- Gross Mechanical Output
- 559 kWm
- Typical Electrical Output
- 554-625 kVA (444-500 kWe)
- Rated Speed
- 1500 rpm
- Prime
- 455 kWe
- Standby
- 500 kWe
- Emissions
- EU Stage V
- Number of Cylinders
- 6 vertical inline
- Bore
- 5.7 in / 145 mm
- Stroke
- 7.2 in / 183 mm
- Displacement
- 1106 in³ / 18.1 l
- Compression Ratio
- 16.0:1
- Aspiration
- Turbocharged aftercooled
- Combustion System
- Mechanical electronic unit injection
- Rotation from Flywheel End
- Anti-clockwise
- Cooling System
- Liquid
- Aftertreatment
- DOC+DPF+SCR
- Typical Alternator Efficiency
- 95%
- Switchable
- yes
- Length
- 43.5 in / 1106 mm
- Width
- 45.8 in / 1164 mm
- Height
- 27.4 in / 695 mm
- Dry Weight
- 4552 lb / 2065 kg
- Note 1
- *Final dimensions dependent on selected options
- Prime Power
- Variable load. Unlimited hours usage with an average load of 70% of the published prime power rating. A 10% overload is available for 1 hour in every 12 hour of operation.
- Standby Power
- Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted.