ATC Contactor Based Bypass Isolation Automatic Transfer Switch

ATC Contactor Based Bypass Isolation Automatic Transfer Switch

ATS ATC Breaker / Contactor

DESCRIPTION

Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass Isolation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times with no interruption. This type of design allows for inspection, maintenance or replacement of the power switching mechanisms with no interruption in electrical service. Contactor -based Bypass Isolation ATS are available from 100A to 1200A.

Product Features

  • ATC-300+ or ATC-800 microprocessor-based controller
  • True RMS voltage and frequency sensing
  • Maintains fully automatic capability while in bypass mode (optional)
  • Single motion rack-out with the door closed
  • Multiple field programmable time delays
  • Switch position indication
  • Source availability indication
  • Source 1 and 2 auxiliary contacts
  • Programmable plant exerciser
  • System test pushbutton
  • Load shed from emergency
  • Mimic diagram
  • Ability to test power switching isolated components

  • Standard Equipment
  • Optional Equipment
  • Specs
  • Docs

Standard Equipment

  • Controls and Wiring
    • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
  • Enclosure
    • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.

Optional Equipment

  • Available Options
    • Space heaters
    • 2- or 4-position test switch
    • Multi-meter options available
    • Open, closed or delayed transition
    • Drawout capabilities on both ATS bypass portions and power switching devices completely interchangeable between ATS and bypass units
    • Load sequencing contacts
    • Dual drawout type is field configurable for top or bottom conduit entry
    • Field selectable, multi ratio, control voltage transformer 50/60 Hz
    • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
    • Remote communications
    • Surge suppression
    • Selectable automatic or non-automatic operation
  • Optional Delayed Transition includes:
    • Time delay neutral
    • Pre-transfer signal with 1 N.O. and 1 N.C. contacts

Specs

Overview

Long Name:
ATC Contactor Based Bypass Isolation Automatic Transfer Switch
Name:
ATC Contactor Based Bypass Isolation Automatic Transfer Switch
Brand:
Caterpillar
Status:
Current

Technical Summary

Rating Range
100 to 1200A
Transfer Type
Bypass Isolation
Switch Type
Contactor Based

Ratings

Control Power
100-1200A 2-, 3-, 4-pole
System Voltage Application
120 - 600 Vac, 50/60 Hz
Withstand
Up to 65 kAIC withstand
Applicable Testing
CSA C22.2 No. 178 certified
IBC 2006, CBC 2007 and OSHPD

SEE HOW ATC Contactor Based Bypass Isolation Automatic Transfer Switch COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

ATS ATC Breaker / Contactor
ATC Contactor Based Bypass Isolation Automatic Transfer Switch
ATS ATC Breaker / Contactor
Brand
Caterpillar
Status
Current
Rating Range
100 to 1200A
Transfer Type
Bypass Isolation
Switch Type
Contactor Based
Control Power
100-1200A 2-, 3-, 4-pole
System Voltage Application
120 - 600 Vac, 50/60 Hz
Applicable Testing
CSA C22.2 No. 178 certified<br>IBC 2006, CBC 2007 and OSHPD
ATS ATC Breaker / Contactor
ATC Molded Case Circuit Breaker & Molded Case Switch ATS
ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
Brand
Caterpillar
Status
Current
Rating Range
30-1000A
Transfer Type
Open transition
Switch Type
Molded Case
Control Power
30-1000A 2, 3, or 4 Pole, 100% Rated
System Voltage Application
120 - 600 Vac, 50/60 Hz
Applicable Testing
CSA C22.2 No. 178 certified<br>IBC 2006, CBC 2007 and OSHPD
ATS ATC Breaker / Contactor
ATC Contactor-Based Automatic Transfer Switch
ATC Contactor-Based Automatic Transfer Switch
Brand
Caterpillar
Status
Current
Rating Range
40-1600A
Transfer Type
Open / Closed Transition
Switch Type
Contactor Based
Control Power
Wall Mount 40-600A 2 or 3 Pole<br>Floor Standing 600A 4 Pole & 800-1200A 2, 3, or 4 Pole
System Voltage Application
Up to 600 Vac, 50/60 Hz
Applicable Testing
UL 1008 listed, CSA C22.2 No. 178 certified, IBC 2006, CBC 2007 and OSHPD