C15 (60 Hz)

C15 Generator Set

C15 (50 HZ) 320-500 kVA Diesel Generator models are developed with specific power needs in mind, allowing a wide range of customization to fit your use.

C15 Rear Right

DESCRIPTION

The C15 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 320 to 500 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. The engines are certified Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards.Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.Electric Power

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.3 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

  • Standard Equipment
  • Optional Equipment
  • Specs
  • Docs

Standard Equipment

  • Air Inlet
    • Air cleaner
  • Air System
    • Turbocharger
    • Air cleaner - Non canister disposable paper filter
    • Aftercooler core
  • Control Panel
    • GCCP 1.3
    • GCCP 1.3 Genset Controller
  • Cooling
    • Package mounted radiator
  • Cooling System
    • Caterpillar extended life coolant
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guard
    • Coolant drain line with valve
  • Exhaust
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank/base supplied
    • Exhaust flange outlet
  • Fuel
    • Secondary fuel filters
    • Primary fuel filter with integral water separator
    • Fuel priming pump
  • Fuel System
    • Primary fuel filter w/integral water separator and secondary filter
    • Fuel priming pump
    • Engine fuel transfer pump
    • Flexible fuel lines
    • Fuel cooler
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • IP23 Protection
  • Power Termination
    • Busbar
  • Generator and Attachments
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Integrated voltage regulator (IVR)
    • Segregated low voltage (AC/DC) wiring panel
    • Optional LC Frame generator - IP23 Protection
    • Power center, IP22
    • A Frame generator - IP21 Protection
  • Mounting
    • Rubber vibration isolators
  • Governing System
    • Cat electronic governor (ADEM A4).
  • Lube System
    • Oil cooler
    • Oil drain valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting/Charging
    • 24 Volt battery with rack and cables
    • 24 volt starting motor
    • Batteries
  • General
    • Engine and alternator pre paint, Caterpillar yellow
    • Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment

  • Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
  • Exhaust
    • Industrial, residential, critical mufflers
  • Certifications
    • EU Certificate of Conformance (CE)
    • Global certification for CIS
  • Circuit breakers
    • Shunt trip for IEC circuit breaker
    • Padlockable circuit breaker device
    • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
    • Auxiliary contacts, circuit breaker
    • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
    • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • Power terminal strip
  • Generator
    • Oversize and premium generators
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Control Panels
    • GCCP 1.4
    • Volt free contacts
    • Local annunciator
    • Remote annunciator module
    • Local alarm horn
    • Oil temperature displays
    • Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
  • Starting/Charging
    • Jacket water heater
    • Charging alternator
    • Heavy duty starting system
    • Battery chargers
    • Oversize batteries
  • Cooling System
    • Stone guards
    • Radiator duct flange
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
  • General
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • CSA Certification
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EEC Declaration of Conformity
    • Integral & sub-base UL listed dual wall fuel tanks
    • Automatic transfer switches (ATS)
    • Single or dual wall sub-base fuel tanks
    • The following options are based on regional and product configuration:
    • EU Certificate of Conformance (CE)
    • Single or dual wall integral fuel tanks
    • Narrow, wide or skid base
    • UL 2200 package
  • Exhaust System
    • Engine mounted muffler
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • 6 and 8 inch elbow kit
    • Manifold and turbocharger guards
    • Flexible exhaust fittings
    • 6 and 8 inch flange GP
  • Fuel System
    • Manual fuel transfer pump
    • Dual wall fuel tank base
    • Fuel transfer system controls
  • Generator and Attachments
    • Space heaters
    • Permanent magnet excitation (PMG) generator
    • Ingress protection
    • LC frame generator
    • Oversize A Frame generator
    • LC frame CIP generator
    • CIP A Frame generator
    • Oversize LC frame generator
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base
  • Special Test / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Battery disconnect switch
    • Jacket water heater

Specs

Overview

Long Name:
C15 Generator Set
Name:
C15 (60 Hz)
Brand:
Cat
Status:
Current

Generator Set Specifications

Maximum Rating
500 ekW
Minimum Rating
320 ekW
Emissions/Fuel Strategy
Low Fuel, Tier 2, Tier 3, EU Stage IIIA
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 RPM
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.4 in / 137.2 mm
Stroke
6.75 in / 171.4 mm
Displacement
927.56 in³ / 15.2 l
Compression Ratio
16.1:1
Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
168.2 in / 4273 mm
Width - Maximum
81 in / 2058 mm
Height - Maximum
126.3 in / 3209 mm

SEE HOW C15 (60 Hz) COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Diesel Generator Sets
C15 (60 Hz)
C15 Rear Right
Brand
Cat
Status
Current
Maximum Rating
500 ekW
Minimum Rating
320 ekW
Emissions/Fuel Strategy
Low Fuel, Tier 2, Tier 3, EU Stage IIIA
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 RPM
Duty Cycle
Standby, Prime
Engine Model
C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.4 in / 137.2 mm
Stroke
6.75 in / 171.4 mm
Displacement
927.56 in³ / 15.2 l
Compression Ratio
16.1:1
Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Governor Type
Adem™A4
Length - Maximum
168.2 in / 4273 mm
Width - Maximum
81 in / 2058 mm
Height - Maximum
126.3 in / 3209 mm
Diesel Generator Sets
C15 (60 Hz)
C15 Rear Right
Brand
Cat
Status
Current
Maximum Rating
500 ekW
Minimum Rating
400 ekW
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.4 in / 137.2 mm
Stroke
6.75 in / 171.4 mm
Displacement
927.56 in³ / 15.2 l
Compression Ratio
16.1:1
Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Governor Type
Adem™A4
Length - Maximum
168.2 in / 4273 mm
Width - Maximum
81 in / 2058 mm
Height - Maximum
82.4 in / 2092 mm
Diesel Generator Sets
C175-16 (50 Hz)
C175-16 Diesel Generator Sets
Brand
Cat
Status
Current
Maximum Rating
3100 kVA
Minimum Rating
2500 kVA
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 11000 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Engine Model
C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.89 in / 175 mm
Stroke
8.66 in / 220 mm
Displacement
5166.88 in³ / 84.7 l
Compression Ratio
16.7:1
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Governor Type
ADEM� A4
Length - Maximum
311 in / 7900 mm
Width - Maximum
108.5 in / 2786 mm
Height - Maximum
130.2 in / 3307 mm